Visualization of viscous fingering in chromatographic columns

被引:77
作者
Broyles, BS
Shalliker', RA
Cherrak, DE
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Dept Chem, Oak Ridge, TN 37831 USA
[3] Oak Ridge Natl Lab, Analyt Sci Div, Oak Ridge, TN 37831 USA
关键词
viscous fingering; preparative chromatography;
D O I
10.1016/S0021-9673(98)00568-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A 17 mm I.D. glass column, packed with YMC-15 (spherical C-18 silica, 30 mu m particles) as the stationary phase and used with carbon tetrachloride as the mobile phase provided a suitable system for the visual observation of viscous fingering inside the packed bed, after the cylindrical lens effect had been canceled. Such a system appears nearly transparent due to the close matching of the refractive indices of the mobile and the stationary phases. The profiles of the bands obtained upon the injection of a flat pulses of a solvent of different refractive index were readily observed. On-column detection using a 35 mm photographic camera was employed for the direct recording of band profiles. A toluene UV marker was used to record subsequent elution profiles via UV detection. The influence of the sample viscosity, the mobile phase flow-rate, and the injection volume on the extent of viscous fingering and band broadening were studied. Viscous fingering was shown to increase with increasing difference between the viscosity of the sample injected and the mobile phase. Viscous fingers were more clearly delineated at higher flow-rates, but band distortion was observed even at flow-rates as low as 0.2 ml min(-1). The degree of band distortion was observed to increase with increasing volume injected. Finally, viscous fingering was found to be a reversible process, as previously reported. (C) 1998 Elsevier Science B.V All rights reserved.
引用
收藏
页码:173 / 187
页数:15
相关论文
共 24 条
  • [1] BAYER E, 1995, J CHROMATOGR A, V704, P3716
  • [2] STABILITY OF VISCOUS FINGERING
    BENSIMON, D
    [J]. PHYSICAL REVIEW A, 1986, 33 (02): : 1302 - 1308
  • [3] Influence of differences between sample and mobile phase viscosities on the shape of chromatographic elution profiles
    Castells, RC
    Castells, CB
    Castillo, MA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 775 (1-2) : 73 - 79
  • [4] PORE-SCALE DIFFERENCE BETWEEN MISCIBLE AND IMMISCIBLE VISCOUS FINGERING IN POROUS-MEDIA
    CHEN, JD
    [J]. AICHE JOURNAL, 1987, 33 (02) : 307 - 311
  • [5] Viscous fingering: a systematic study of viscosity effects in methanol-isopropanol systems
    Cherrak, D
    Guernet, E
    Cardot, P
    Herrenknecht, C
    Czok, M
    [J]. CHROMATOGRAPHIA, 1997, 46 (11-12) : 647 - 654
  • [6] CHERRAK DE, 1996, THESIS U PARIS 11
  • [7] EFFECT OF SAMPLE VISCOSITY IN HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY AND ITS CONTROL
    CZOK, M
    KATTI, AM
    GUIOCHON, G
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2): : 705 - 719
  • [8] ALIGNED FIBER COLUMNS FOR SIZE-EXCLUSION CHROMATOGRAPHY
    CZOK, M
    GUIOCHON, G
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 506 : 303 - 317
  • [9] Chemical imaging of multicomponent viscous fingering in chromatography
    Dickson, ML
    Norton, TT
    Fernandez, EJ
    [J]. AICHE JOURNAL, 1997, 43 (02) : 409 - 418
  • [10] PHILOSOPHY OF THE PURITY AND IDENTITY OF ORGANIC COMPOUNDS
    EYRING, H
    [J]. ANALYTICAL CHEMISTRY, 1948, 20 (02) : 98 - 100