Immunochromatographic analysis of bovine growth hormone releasing factor involving reversed-phase high-performance liquid chromatography immunodetection

被引:21
作者
Cho, BY
Zou, HF
Strong, R
Fisher, DH
Nappier, J
Krull, IS
机构
[1] NORTHEASTERN UNIV,DEPT CHEM,BOSTON,MA 02115
[2] UNIV KANSAS,CTR BIOANALYT RES,LAWRENCE,KS 66047
[3] PHARMACIA UPJOHN INC,ANIM HLTH & DRUG METAB,KALAMAZOO,MI 49001
关键词
immunodetection; immunoaffinity columns; detection; LC; growth hormones; antibodies; antigens; peptides;
D O I
10.1016/0021-9673(96)00356-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed high-performance immunoaffinity chromatography (HPIAC) methods for the detection and quantitation of bovine growth hormone releasing factor (GHRF), which could also be applicable to its metabolites in biofluids, These approaches have involved a combination of IAC using immobilized antibody (Ab) to GHRF, together with reversed-phase high-performance liquid chromatography (RP-HPLC) separations of initially isolated and concentrated protein, followed by selective detection, involving on-line immunodetection (ID) schemes. ID methods involved HPIAC supports of the Ab, together with synthesized Ab-fluorescein isothiocyanate conjugates. We have demonstrated optimization methods for each step of the entire hyphenated technique (IAC-HPLC-LD), and then actually quantitated GHRF using this overall system. The minimum detectable concentration was about 1 ng/5 ml (200 ppt) with fluorescence detection (excitation wavelength, 490 nm; emission wavelength, 510-650 nm). We have also tested a single blind, spiked biological sample (bovine plasma), spiked with a known level of GHRF. Accuracy (7.4%) and precision (S.D.=+/-22%) were quite acceptable for a double immunoassay method.
引用
收藏
页码:181 / 194
页数:14
相关论文
共 34 条
  • [1] PERFUSION CHROMATOGRAPHY PACKING MATERIALS FOR PROTEINS AND PEPTIDES
    AFEYAN, NB
    FULTON, SP
    REGNIER, FE
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2): : 267 - 279
  • [2] FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY
    AFEYAN, NB
    GORDON, NF
    MAZSAROFF, I
    VARADY, L
    FULTON, SP
    YANG, YB
    REGNIER, FE
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01): : 1 - 29
  • [3] AUTOMATED REAL-TIME IMMUNOASSAY OF BIOMOLECULES
    AFEYAN, NB
    GORDON, NF
    REGNIER, FE
    [J]. NATURE, 1992, 358 (6387) : 603 - 604
  • [4] AFEYAN NB, 1992, HPLC 92 BALT JUN 25
  • [5] GROWTH HORMONE-RELEASING FACTOR FROM OVINE AND CAPRINE HYPOTHALAMUS - ISOLATION, SEQUENCE-ANALYSIS AND TOTAL SYNTHESIS
    BRAZEAU, P
    BOHLEN, P
    ESCH, F
    LING, N
    WEHRENBERG, WB
    GUILLEMIN, R
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1984, 125 (02) : 606 - 614
  • [6] PRESENCE OF GROWTH HORMONE-RELEASING FACTOR-LIKE IMMUNOREACTIVITY IN RAT DUODENUM
    BRUHN, TO
    MASON, RT
    VALE, WW
    [J]. ENDOCRINOLOGY, 1985, 117 (04) : 1710 - 1712
  • [7] QUANTITATIVE MEASUREMENT OF FC RECEPTOR ACTIVITY ON HUMAN PERIPHERAL-BLOOD MONOCYTES AND THE MONOCYTE-LIKE CELL-LINE, U937, BY LASER FLOW-CYTOMETRY
    CHRISTENSEN, J
    LESLIE, RGQ
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 132 (02) : 211 - 219
  • [8] TANDEM CHROMATOGRAPHIC-IMMUNOLOGICAL ANALYSES
    DEFRUTOS, M
    REGNIER, FE
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (01) : A17 - &
  • [9] CHROMATOGRAPHY IMMUNOLOGY COUPLING, A POWERFUL TOOL FOR ENVIRONMENTAL-ANALYSIS
    DEFRUTOS, M
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (03) : 133 - 140
  • [10] FLUORESCEIN LABELING OF FAB WHILE PRESERVING SINGLE THIOL
    DERBALIAN, GP