Brain tumors:: Full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T -: Initial experience

被引:76
作者
Krautmacher, C [1 ]
Willinek, WA [1 ]
Tschampa, HJ [1 ]
Born, M [1 ]
Träber, F [1 ]
Gieseke, J [1 ]
Textor, HJ [1 ]
Schild, HH [1 ]
Kuhl, CK [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
D O I
10.1148/radiol.2373041672
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively and intraindividually compare the effect of magnetic resonance (MR) imaging at a higher magnetic field strength (3.0 T) on contrast-to-noise ratio (CNR) at different doses of a T1-shortening contrast agent in patients with contrast-enhancing brain lesions, with 1.5-T MR imaging as a reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for all patient and volunteer studies. Twelve patients (six women, six men; mean age, 58 years; range, 29-76 years) with 12 enhancing brain lesions (11 patients with primary brain tumors and one with a solitary cerebral metastasis) underwent contrast material-enhanced MR imaging three times, on three separate days: once at 1.5 T with a full dose of 0.10 mmol/kg gadopentetate dimeglumine, once at 3.0 T with a full dose, and once at 3.0 T with half that dose, 0.05 mmol/kg. The same contrast-enhanced T1-weighted spin-echo images (repetition time msec/echo time msec, 500/12; section thickness, 5 mm; matrix, 256 X 205) were obtained at both 3.0 T and 1.5 T after prior optimization of parameters at 3.0 T. The number and conspicuity of enhancing brain lesions were assessed with blinded clinical image reading. Signal-to-noise ratio and CNR were determined with region of interest analysis of enhancing lesions and normal contralateral white matter. For 3.0 T with half the standard dose and with the full dose, CNR of lesions was intraindividually compared with CNR at 1.5 T with the full dose by using the Wilcoxon matched-pairs signed rank test. RESULTS: At 3.0 T and full dose, CNR was 2.8-fold higher than that at 1.5 T and full dose (P <.001). At the same time, higher lesion conspicuity at clinical image reading was observed. With only half the standard dose, MR imaging at 3.0 T still yielded higher CNR (1.3-fold higher) than that with full dose at 1.5 T (P <.01). CONCLUSION: With the same amount of contrast agent, MR imaging at 3.0 T offered a significantly higher CNR of enhancing cerebral lesions, compared with that at 1.5 T; even with the dose reduced by half, CNR was still higher at 3.0 T. (c) RSNA, 2005.
引用
收藏
页码:1014 / 1019
页数:6
相关论文
共 18 条
[1]   Enhancement of cerebral diseases: How much contrast agent is enough? Comparison of 0.1, 0.2, and 0.3 mmol/kg gadoteridol at 0.2 T with 0.1 mmol/kg gadoteridol at 1.5 T [J].
Brekenfeld, C ;
Foert, E ;
Hundt, W ;
Kenn, W ;
Lodeann, KP ;
Gehl, HB .
INVESTIGATIVE RADIOLOGY, 2001, 36 (05) :266-275
[2]  
CHANG KH, 1994, AM J NEURORADIOL, V15, P1413
[3]   How much contrast is enough? Dependence of enhancement on field strength and MR pulse sequence [J].
Elster, AD .
EUROPEAN RADIOLOGY, 1997, 7 (Suppl 5) :S276-S280
[4]  
HAUSTEIN J, 1992, AM J NEURORADIOL, V13, P1199
[5]   TRIPLE-DOSE VERSUS STANDARD-DOSE GADOPENTETATE DIMEGLUMINE - A RANDOMIZED STUDY IN 199 PATIENTS [J].
HAUSTEIN, J ;
LANIADO, M ;
NIENDORF, HP ;
LOUTON, T ;
BECK, W ;
PLANITZER, J ;
SCHOFFEL, M ;
REISER, M ;
KAISER, W ;
SCHORNER, W ;
HIERHOLZER, J ;
TRAUPE, H ;
HAMM, B .
RADIOLOGY, 1993, 186 (03) :855-860
[6]   CEREBRAL INFARCTION - EFFECTS OF DOSE AND MAGNETIZATION-TRANSFER SATURATION AT GADOLINIUM-ENHANCED MR-IMAGING [J].
MATHEWS, VP ;
KING, JC ;
ELSTER, AD ;
HAMILTON, CA .
RADIOLOGY, 1994, 190 (02) :547-552
[7]   Effects of contrast dose, delayed imaging, and magnetization transfer saturation on gadolinium-enhanced MR imaging of brain lesions [J].
Mathews, VP ;
Caldemeyer, KS ;
Ulmer, JL ;
Nguyen, H ;
Yuh, WTC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :14-22
[8]  
MAYR NA, 1994, AM J NEURORADIOL, V15, P1053
[9]   Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla [J].
Nöbauer-Huhmann, IM ;
Ba-Ssalamah, A ;
Mlynarik, V ;
Barth, M ;
Schöggl, A ;
Heimberger, K ;
Matula, C ;
Fog, A ;
Kaider, A ;
Trattnig, S .
INVESTIGATIVE RADIOLOGY, 2002, 37 (03) :114-119
[10]   Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents [J].
Rinck, PA ;
Muller, RN .
EUROPEAN RADIOLOGY, 1999, 9 (05) :998-1004