Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity

被引:38
作者
Baudoin, A. [1 ]
Skalli, W. [1 ]
De Guise, J. A. [2 ]
Mitton, D. [1 ]
机构
[1] ENSAM, CNRS, UMR 8005, Lab Biomecan, F-75013 Paris, France
[2] ETS CRCHUM, Lab Rech Imager & Orthoped Montreal, Montreal, PQ, Canada
关键词
biplanar X-rays; femur; 3D reconstruction; low dose X-ray; model customization;
D O I
10.1007/s11517-008-0353-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Although feasibility of accurate 3D reconstruction of the proximal epiphysis of the femur from biplanar X-rays (frontal and lateral) has been assessed, in vivo application is limited due to bone superposition. The aim of this study was to propose a specific algorithm to get accurate and reproducible, low dose in vivo 3D reconstruction. To achieve this goal, a parametric subject-specific model was introduced as a priori knowledge. This geometric model was based on a database based on proximal epiphysis of 60 femurs. The accuracy was estimated using comparisons to CT scans on 13 cadaveric femurs, then in vivo intra- and inter- observer reproducibility was assessed using a set of 23 femurs. The mean for the relative difference was 0.2 mm for the in vitro 3D accuracy. The mean error was 1.0 mm with maximum value of 5.1 mm in ideal conditions (in vitro). The confidence interval for the inter-observer reproducibility was within +/- 2.2 mm. This method gave us a reproducible tool in order to get in vivo 3D reconstructions of the femur proximal epiphysis from biplanar X-rays.
引用
收藏
页码:799 / 805
页数:7
相关论文
共 20 条
[1]
Benameur S, 2002, Stud Health Technol Inform, V91, P281
[2]
3D/2D registration and segmentation of scoliotic vertebrae using statistical models [J].
Benameur, S ;
Mignotte, M ;
Parent, S ;
Labelle, H ;
Skalli, W ;
de Guise, J .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (05) :321-337
[3]
Volumetric quantitative computed tomography of the proximal femur: relationships linking geometric and densitometric variables to bone strength. Role for compact bone [J].
Bousson, V ;
Bras, A ;
Roqueplan, F ;
Kang, Y ;
Mitton, D ;
Kolta, S ;
Bergot, C ;
Skalli, W ;
Vicaut, E ;
Kalender, W ;
Engelke, K ;
Laredo, JD .
OSTEOPOROSIS INTERNATIONAL, 2006, 17 (06) :855-864
[4]
A new 2D and 3D imaging approach to musculo-skeletal physiology and pathology with low-dose radiation and the standing position : the EOS system [J].
Dubousset, J ;
Charpak, G ;
Dorion, I ;
Skalli, W ;
Lavaste, F ;
Deguise, J ;
Kalifa, G ;
Ferey, S .
BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2005, 189 (02) :287-297
[5]
Fleute M, 1999, Med Image Anal, V3, P209, DOI 10.1016/S1361-8415(99)80020-6
[6]
GAUTSCH TL, 1994, CLIN ORTHOP RELAT R, P138
[7]
A novel system of four-dimensional motion analysis after total hip arthroplasty [J].
Hagio, K ;
Sugano, N ;
Nishii, T ;
Miki, H ;
Otake, Y ;
Hattori, A ;
Suzuki, N ;
Yonenobu, K ;
Yoshikawa, H ;
Ochi, T .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :665-670
[8]
Low-dose computed tomography: A solution for in vivo medical imaging and accurate patient-specific 3D bone modeling? [J].
Jan, Serge Van Sint ;
Sobzack, Stephane ;
Dugailly, Pierre-Michel ;
Feipel, Veronique ;
Lefevre, Philippe ;
Lufimpadio, Jean-Louis ;
Salvia, Patrick ;
Viceconti, Marco ;
Rooze, Marcel .
CLINICAL BIOMECHANICS, 2006, 21 (09) :992-998
[9]
Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children [J].
Kalifa, G ;
Charpak, Y ;
Maccia, C ;
Fery-Lemonnier, E ;
Bloch, J ;
Boussard, JM ;
Attal, M ;
Dubousset, J ;
Adamsbaum, C .
PEDIATRIC RADIOLOGY, 1998, 28 (07) :557-561
[10]
Laporte S., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P1, DOI 10.1080/1025584031000065956