Improving the sensitivity of stereotactic core biopsy to diagnose ductal carcinoma in situ of the breast:: a mathematical model

被引:5
作者
Coombs, NJ
Laddie, JRL
Royle, GT [1 ]
Rubin, CM
Briley, MS
机构
[1] Royal S Hants Hosp, Dept Breast Surg, Southampton SO14 0YG, Hants, England
[2] Royal S Hants Hosp, Dept Radiol, Southampton SO14 0YG, Hants, England
[3] Southampton & Salisbury Breast Screening Unit, Southampton, Hants, England
关键词
D O I
10.1259/bjr.74.878.740123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stereotactic core biopsy (SCB) is performed on mammographically suspicious, nonpalpable lesions of the breast. Reported sensitivities of SCB for the detection of ductal carcinoma in situ (DCIS) vary from 41% to 93%. We have developed a simple mathematical model to predict the probability of retrieving at least one diagnostic core from a focus of DCIS. We make recommendations of the number of samples needed for different sized areas of microcalcification. The sensitivity of SCB is affected by needle placement accuracy, diameter of the area of microcalcification (d), histological density of DCIS (x) (calculated as 7.5% by previous studies) and number of core samples (n) removed. The probability of achieving at least one representative core sufficient for diagnosis (P-(core)) is defined as: P-(core) = 1 - (1 + rho{[l - (x/100)](d) - 1})(n), where rho is the probability of a SCB accurately targeting the area of microcalcification. At least seven core samples should be removed in small foci (<5 mm) of DCIS to achieve a 0.75 probability of an accurate diagnosis. The probability of a diagnostic biopsy of larger areas of DCIS (> 10 mm) is 0.95 when five cores are removed. This formula serves as an explanation to patients why SCB may fail to diagnose DCIS, and justifies the retrieval of more core samples to increase the probability of an accurate diagnosis and to reduce the chance of a non-representative core. In the absence of sufficient samples, a wire-guided open biopsy is necessary to exclude DCIS.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 10 条
[1]   The impact of stereotactic large-core needle biopsy in the treatment of patients with nonpalpable breast lesions: a study of diagnostic accuracy in 510 consecutive cases [J].
Andreu, FJ ;
Sentis, M ;
Castanier, E ;
Gallardo, X ;
Jurado, I ;
Diaz-Ruiz, MJ ;
Mendez, I ;
Rey, M ;
Florensa, R .
EUROPEAN RADIOLOGY, 1998, 8 (08) :1468-1474
[2]   Histologic-radiologic correlation of mammographically detected microcalcification in stereotactic core biopsies [J].
Dahlstrom, JE ;
Sutton, S ;
Jain, S .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1998, 22 (02) :256-259
[3]   Diagnostic accuracy of stereotactic core biopsy in a mammographic breast cancer screening programme [J].
Dahlstrom, JE ;
Jain, S ;
Sutton, T ;
Sutton, S .
HISTOPATHOLOGY, 1996, 28 (05) :421-427
[4]   Stereotactic 14 gauge core-biopsy of the breast: Results from 101 patients [J].
Frayne, J ;
Sterrett, GF ;
Harvey, J ;
Goodwin, P ;
Townsend, J ;
Ingram, D ;
Parsons, RW .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (09) :585-591
[5]   STEREOTAXIC 14-GAUGE BREAST BIOPSY - HOW MANY CORE BIOPSY SPECIMENS ARE NEEDED [J].
LIBERMAN, L ;
DERSHAW, DD ;
ROSEN, PP ;
ABRAMSON, AF ;
DEUTCH, BM ;
HANN, LE .
RADIOLOGY, 1994, 192 (03) :793-795
[6]   RADIOGRAPHY OF MICROCALCIFICATIONS IN STEREOTAXIC MAMMARY CORE BIOPSY SPECIMENS [J].
LIBERMAN, L ;
EVANS, WP ;
DERSHAW, DD ;
HANN, LE ;
DEUTCH, BM ;
ABRAMSON, AF ;
ROSEN, PP .
RADIOLOGY, 1994, 190 (01) :223-225
[7]   Stereotactic 14G core biopsy of non-palpable breast cancer: What is the relationship between the number of core samples taken and the sensitivity for detection of malignancy? [J].
Rich, PM ;
Michell, MJ ;
Humphreys, S ;
Howes, GP ;
Nunnerley, HB .
CLINICAL RADIOLOGY, 1999, 54 (06) :384-389
[8]  
SWINSCOW TDV, 1996, PROBABILITIES RELATE, P133
[9]   Comparison of mammographically guided breast biopsy techniques [J].
Velanovich, V ;
Lewis, FR ;
Nathanson, SD ;
Strand, VF ;
Talpos, GB ;
Bhandarkar, S ;
Elkus, R ;
Szymanski, W ;
Ferrara, JJ .
ANNALS OF SURGERY, 1999, 229 (05) :625-633
[10]  
WEIBEL RR, 1971, STEREOLOGICAL TECHNI, V3, P237