Reliability analysis for manual adolescent idiopathic scoliosis measurements

被引:88
作者
Kuklo, TR
Potter, BK
Polly, DW
O'Brien, MF
Schroeder, TM
Lenke, LG
机构
[1] Walter Reed Army Med Ctr, Dept Orthopaed & Rehabil, Washington, DC 20307 USA
[2] Uniformed Serv Univ Hlth Sci, Dept Surg, Bethesda, MD 20814 USA
[3] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
[4] Miami Childrens Hosp, Dept Orthopaed Surg, Miami, FL USA
[5] Washington Univ, Sch Med, Dept Spinal Surg, St Louis Shriners Hosp Children, St Louis, MO USA
[6] Washington Univ, Dept Orthopaed Surg, St Louis, MO USA
关键词
intraobserver reliability; interobserver reliability; manual measurement; radiographic process measure; adolescent idiopathic scoliosis;
D O I
10.1097/01.brs.0000153702.99342.9c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Manual radiographic measurement analysis. Objectives. To determine the intraobserver and interobserver reliability of numerous radiographic process measures used in the assessment of adolescent idiopathic scoliosis. Summary of Background Data. Analysis of scoliosis requires a thorough radiographic evaluation to completely assess the deformity. Numerous radiographic process measures have been studied extensively and used for outcomes assessment and thus become the de facto standard of care. However, many of these measures have not been evaluated to determine the reliability and reproducibility. Validation of radiographic process measures is necessary to compare these measures with patient-focused outcome measures, as well as to permit valid comparison of different surgical techniques. Methods. Thirty complete sets of long-cassette scoliosis radiographs (anteroposterior [AP], lateral and side-bending preoperative and AP, and lateral postoperative) were analyzed by three independent experienced observers on two separate occasions. Coronal image measures included the coronal Cobb angles, side-bending Cobb, apical vertebral translation, coronal balance, T1 tilt, lowest instrumented vertebrae (LIV) tilt, angulation of the disc below the LIV, apical vertebral rotation (Nash-Moe), and Risser sign; sagittal measures included T2-T5, T5-T12, T2-T12, T10-L2, T12-S1, and sagittal balance. Intraobserver and interobserver reliability for each measure was then assessed. Results. The vast majority of the radiographic process measures assessed demonstrated good to excellent or excellent intraobserver and interobserver reliability. However, the angulation of the disc below the LIV demonstrated only fair interobserver reliability for postoperative measurements (rho = 0.59). Likewise, Risser grade measurements reflected good intraobserver (0.81-0.99) but only fair interobserver reliability (0.60-0.70). Apical vertebral rotation assessed by the technique of Nash and Moe produced good intraobserver reliability before surgery (0.74-0.85) but only fair reliability after surgery (0.50-0.85). The interobserver reliability for apical Nash-Moe rotation was fair to poor (0.53-0.59). For T2-T5 regional kyphosis, intraobserver (0.22-0.83) and interobserver (0.33-0.47) reliability was generally poor. Overall, the reliability of postoperative measurements tended to be decreased relative to preoperative values, likely due to instrumentation overlying radiographic landmarks. Conclusions. Most of the radiographic process measures evaluated in this study demonstrated good or excellent reliability. The reliability of measuring the angulation of the disc below the LIV, the apical Nash-Moe rotation, and Risser grading was decreased relative to other measures. The reliability of measuring T2-T5 regional kyphosis was disappointing and poor. With regards to the other 13 measures assessed, our findings support the use of these process measures obtained by experienced deformity surgeons via manual measurement for routine clinical and academic purposes.
引用
收藏
页码:444 / 454
页数:11
相关论文
共 80 条
  • [1] ESTIMATION OF VERTEBRAL ROTATION AND THE SPINAL AND RIB CAGE DEFORMITY IN SCOLIOSIS BY COMPUTER-TOMOGRAPHY
    AARO, S
    DAHLBORN, M
    [J]. SPINE, 1981, 6 (05) : 460 - 467
  • [2] Aronsson DD, 1996, J SPINAL DISORD, V9, P214
  • [3] Asher MA, 2003, 38 ANN SCOL RES SOC
  • [4] BEHENSKY H, 2003, 10 INT M ADV SPIN TE
  • [5] SEGMENTAL ANALYSIS OF THE SAGITTAL PLANE ALIGNMENT OF THE NORMAL THORACIC AND LUMBAR SPINES AND THORACOLUMBAR JUNCTION
    BERNHARDT, M
    BRIDWELL, KH
    [J]. SPINE, 1989, 14 (07) : 717 - 721
  • [6] Comparison of anterior and posterior instrumentation for correction of adolescent thoracic idiopathic scoliosis
    Betz, RR
    Harms, J
    Clements, DH
    Lenke, LG
    Lowe, TG
    Shufflebarger, HL
    Jeszensky, D
    Beele, B
    [J]. SPINE, 1999, 24 (03) : 225 - 239
  • [7] Complications and predictive factors for the successful treatment of flatback deformity (fixed sagittal imbalance)
    Booth, KC
    Bridwell, KH
    Lenke, LG
    Baldus, CR
    Blanke, KM
    [J]. SPINE, 1999, 24 (16) : 1712 - 1720
  • [8] Process measures and patient parent evaluation of surgical management of spinal deformities in patients with progressive flaccid neuromuscular scoliosis (Duchenne's muscular dystrophy and spinal muscular atrophy)
    Bridwell, KH
    Baldus, C
    Iffrig, TM
    Lenke, LG
    Blanke, K
    [J]. SPINE, 1999, 24 (13) : 1300 - 1309
  • [9] BRIDWELL KH, 2001, CLIN ORTHOP RELAT R, V384, P35
  • [10] METHOD FOR DETERMINING VERTEBRAL BODY POSITIONS IN THE SAGITTAL PLANE USING SKIN MARKERS
    BRYANT, JT
    REID, JG
    SMITH, BL
    STEVENSON, JM
    [J]. SPINE, 1989, 14 (03) : 258 - 265