Effects of intraaortic balloon pumping on septal arterial blood flow velocity waveform during severe left main coronary artery stenosis

被引:35
作者
Kimura, A [1 ]
Toyota, E [1 ]
Lu, SF [1 ]
Goto, M [1 ]
Yada, T [1 ]
Chiba, Y [1 ]
Ebata, J [1 ]
Tachibana, H [1 ]
Ogasawara, Y [1 ]
Tsujioka, K [1 ]
Kajiya, F [1 ]
机构
[1] KAWASAKI MED SCH, DEPT MED ENGN & SYST CARDIOL, KURASHIKI, OKAYAMA 70101, JAPAN
关键词
D O I
10.1016/0735-1097(95)00561-7
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objectives. We sought to evaluate the effect of intraaortic balloon pumping on the phasic blood velocity waveform into myocardium with severe coronary artery stenosis. Background. In the presence of severe coronary artery stenosis, it is not clear whether intraaortic balloon pumping augments intramyocardial inflow during diastole or changes systolic retro grade blood flow from the myocardium to the extramural coronary arteries. Methods. Using anesthetized open chest dogs (n = 7), we introduced severe stenosis in the left main coronary artery lo reduce the poststenotic pressure to approximately 60 mm Hg (>90% diameter stenosis). Septal arterial blood flea velocities were measured with a 20-MHz, 80-channel ultrasound pulsed Doppler velocimeter, Left anterior descending arterial flow, aortic pressure and poststenotic distal coronary pressure were measured simultaneously. The diastolic anterograde flow integral and systolic retrograde flow integral were compared in the presence and absence of intraaortic balloon pumping. Results. Although intraaortic balloon pumping augmented diastolic aortic pressure, this pressure increase was not effectively transmitted through stenosis. Septal arterial diastolic flow velocity was not augmented, and left anterior descending arterial flow was unchanged during intraaortic balloon pumping. Conclusions. In the presence of severe coronary artery stenosis, intraaortic balloon pumping failed to increase diastolic inflow to the myocardium and did not enhance systolic retrograde flow from the myocardium to the extramural coronary artery. Thus, the major effect of intraaortic balloon pumping on the ischemic heart with severe coronary artery stenosis may be achieved by reducing oxygen demand by systolic unloading.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 29 条
[1]
BREGMAN D, 1975, J THORAC CARDIOV SUR, V70, P1010
[2]
PHASIC CORONARY BLOOD-FLOW VELOCITY IN INTRAMURAL AND EPICARDIAL CORONARY-ARTERIES [J].
CHILIAN, WM ;
MARCUS, ML .
CIRCULATION RESEARCH, 1982, 50 (06) :775-781
[3]
VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[4]
CORONARY PHYSIOLOGY [J].
FEIGL, EO .
PHYSIOLOGICAL REVIEWS, 1983, 63 (01) :1-205
[5]
GEWIRTZ H, 1982, AM J CARDIOL, V50, P829, DOI 10.1016/0002-9149(82)91241-3
[6]
Gill C C, 1973, Ann Thorac Surg, V16, P445
[7]
EFFECT OF INTRACORONARY NITROGLYCERIN ADMINISTRATION ON PHASIC PATTERN AND TRANSMURAL DISTRIBUTION OF FLOW DURING CORONARY-ARTERY STENOSIS [J].
GOTO, M ;
FLYNN, AE ;
DOUCETTE, JW ;
KIMURA, A ;
HIRAMATSU, O ;
YAMAMOTO, T ;
OGASAWARA, Y ;
TSUJIOKA, K ;
HOFFMAN, JIE ;
KAJIYA, F .
CIRCULATION, 1992, 85 (06) :2296-2304
[8]
COMPENSATORY CHANGES OF DISTAL CORONARY VASCULAR BED DURING PROGRESSIVE CORONARY CONSTRICTION [J].
GOULD, KL ;
LIPSCOMB, K ;
CALVERT, C .
CIRCULATION, 1975, 51 (06) :1085-1094
[9]
SIGNIFICANCE OF SUBENDOCARDIAL S-T SEGMENT ELEVATION CAUSED BY CORONARY STENOSIS IN DOG - EPICARDIAL S-T SEGMENT DEPRESSION, LOCAL ISCHEMIA AND SUBSEQUENT NECROSIS [J].
GUYTON, RA ;
MCCLENATHAN, JH ;
NEWMAN, GE ;
MICHAELIS, LL .
AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (03) :373-380
[10]
PRESSURE-FLOW RELATIONS IN CORONARY CIRCULATION [J].
HOFFMAN, JIE ;
SPAAN, JAE .
PHYSIOLOGICAL REVIEWS, 1990, 70 (02) :331-390