Sequence design for magnetic resonance spectroscopic imaging of prostate cancer at 3T

被引:46
作者
Cunningham, CH
Vigneron, DB
Marjanska, M
Chen, AP
Xu, D
Hurd, RE
Kurhanewicz, J
Garwood, M
Pauly, JM
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[3] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN USA
[4] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
[5] GE Med Syst ASL W, Menlo Pk, CA USA
关键词
prostate cancer; high field; spectroscopic imaging; RF pulse design;
D O I
10.1002/mrm.20478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance spectroscopic imaging (MRSI) has proven to be a powerful tool for the metabolic characterization of prostate cancer in patients before and following therapy. The metabolites that are of particular interest are citrate and choline because an increased choline-to-citrate ratio can be used as a marker for cancer. High-field systems offer the advantage of improved spectral resolution as well as increased magnetization. Initial attempts at extending MRSI methods to 3 T have been confounded by the J-modulation of the citrate resonances. A new pulse sequence is presented that controls the J-modulation of citrate at 3 T such that citrate is upright, with high amplitude, at a practical echo time. The design of short (14 ms) spectral-spatial refocusing pulses and trains of nonselective refocusing pulses are described. Phantom studies and simulations showed that upright citrate with negligible sidebands is observed at an echo time of 85 ms. Studies in a human subject verified that this behavior is reproduced in vivo and demonstrated that the water and lipid suppression of the new pulse sequence are sufficient for application in prostate cancer patients. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1033 / 1039
页数:7
相关论文
共 27 条
[2]  
[Anonymous], 1982, 2 DIMENSIONAL NUCL M
[3]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[4]   Design of symmetric-sweep spectral-spatial RF pulses for spectral editing [J].
Cunningham, CH ;
Vigneron, DB ;
Chen, AP ;
Xu, D ;
Hurd, RE ;
Sailasuta, N ;
Pauly, JM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :147-153
[5]  
CUNNINGHAM CH, 2004, P 12 ANN M ISMRM KY, P682
[6]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[7]   Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment [J].
Hennig, J ;
Thiel, T ;
Speck, O .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :816-820
[8]   Proton spectroscopy without water suppression:: The oversampled J-resolved experiment [J].
Hurd, RE ;
Gurr, D ;
Sailasuta, N .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :343-347
[9]   Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer [J].
Kurhanewicz, J ;
Swanson, MG ;
Nelson, SJ ;
Vigneron, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (04) :451-463
[10]   Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging [J].
Le Roux, P ;
Gilles, RJ ;
McKinnon, GC ;
Carlier, PG .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1022-1032