In vivo efficiency of four commercial monopolar radiofrequency ablation systems -: A comparative experimental study in pig liver
被引:41
作者:
Brieger, J
Pereira, PL
Trübenbach, J
Schenk, M
Kröber, SM
Schmidt, D
Aubé, C
Claussen, CD
Schick, F
机构:
[1] Univ Tubingen Hosp, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Gen Surg, D-72076 Tubingen, Germany
[4] Univ Tubingen Hosp, Inst Pathol, D-72076 Tubingen, Germany
关键词:
radiofrequency ablation;
radiofrequency energy;
liver;
in vivo;
D O I:
10.1097/01.rli.0000077122.70885.94
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Rationale and Objectives: To evaluate the efficiency of 4 radio-frequency (RF) systems by assessing the amount of delivered energy for each thermal induced lesion after perfusion mediated RF ablation and to compare the influence of perfusion mediation types on the energy efficiency. Methods: A total of 43 ablations in 16 male landrace pigs with 4 RF devices were performed strictly according to the manufacturers' instructions. Total absorbed energy was computed and then related to 3D volumetry obtained after histopathological evaluation. Sixteen ablations were performed under physiological liver perfusion and 27 ablations with occlusion of portal vein, hepatic artery, or both vessels. Energy efficiency values of the RF systems for different vascular occlusion techniques were compared and analyzed by a nonparametrical rank sum test. Results: Under physiological perfusion, the average energy delivered to produce 1-cm(3) lesion size was calculated to 1650 +/- 929, 3097 +/- 389, 8312 +/- 2068, and 5493 +/- 2306 Watt (.) s/cm(3) for the Berchtold(R), Radionics(TM), Radiotherapeutics(TM), and RITA(R) system, respectively. After perfusion-mediated RF ablation, artery occlusion was not as effective as portal vein occlusion, which reduced the energy to 587 +/- 148, 869 +/- 276, and 903 +/- 394 Watt (.) s/cm(3) for the Berchtold(R), Radionics(TM), and Radiotherapeutics(TM) system, respectively. The occlusion of vessels, portal vein, and artery or portal vein alone increased the energy efficiency compared with physiological liver perfusion or occlusion of the artery (P = 0,003). Conclusions: Under physiological liver perfusion the open perfused system and the internally cooled system provided the best efficiency values with lowest standard deviations. The energy efficiency was increased markedly for all systems after occlusion of the portal vein either alone or in combination with arterial occlusion. Occlusion of the hepatic artery did not improve the efficiency.
引用
收藏
页码:609 / 616
页数:8
相关论文