A Power-Efficient Neural Tissue Stimulator With Energy Recovery

被引:75
作者
Kelly, Shawn K. [1 ,2 ]
Wyatt, John L., Jr. [2 ,3 ]
机构
[1] Ctr Innovat Visual Rehabil, Boston, MA 02130 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
Biomedical engineering; bioelectric potentials; biomedical electrodes; integrated-circuit (IC) design; iridium; neuromuscular stimulation; retinal prosthesis; telemetry; ELECTRICAL-STIMULATION; CHARGE; INJURY; CHIP;
D O I
10.1109/TBCAS.2010.2076384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a power-efficient neural stimulator integrated circuit, designed to take advantage of our understanding of iridium-oxide electrode impedance. It efficiently creates a programmable set of voltage supplies directly from a secondary power telemetry coil, then switches the target electrode sequentially through the voltage steps. This sequence of voltages mimics the voltage of the electrode under the constant current drive, resulting in approximately constant current without the voltage drop of the more commonly used linear current source. This method sacrifices some precision, but drastically reduces the series losses seen in traditional current sources and attains power savings of 53%-66% compared to these designs. The proof-of-concept circuit consumes 125 mu W per electrode and was fabricated in a 1.5-mu m CMOS process, in a die area of 4.76 mm(2).
引用
收藏
页码:20 / 29
页数:10
相关论文
共 26 条
[1]  
[Anonymous], P IEEE ISSCC FEB
[2]  
*ANSI, C9512005 ANSI IEEE
[3]  
ANTHAS WC, 1994, 4 GREAT LAK S VLSI D, P196
[4]   2 NOVEL FULLY COMPLEMENTARY SELF-BIASED CMOS DIFFERENTIAL-AMPLIFIERS [J].
BAZES, M .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1991, 26 (02) :165-168
[5]   CHARGE INJECTION LIMITS OF ACTIVATED IRIDIUM OXIDE ELECTRODES WITH 0.2MS PULSES IN BICARBONATE BUFFERED SALINE [J].
BEEBE, X ;
ROSE, TL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (06) :494-495
[6]  
CAULFIELD RE, 2001, THESIS MIT CAMBRIDGE
[7]  
Cogan Stuart F, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P882
[8]  
DICKINSON AG, 1994, PROCEEDINGS OF THE IEEE 1994 CUSTOM INTEGRATED CIRCUITS CONFERENCE, P282, DOI 10.1109/CICC.1994.379718
[9]   A method for generating precise temporal patterns of retinal spiking using prosthetic stimulation [J].
Fried, SI ;
Hsueh, HA ;
Werblin, FS .
JOURNAL OF NEUROPHYSIOLOGY, 2006, 95 (02) :970-978
[10]   Thermal elevation in the human eye and head due to the operation of a retinal prosthesis [J].
Gosalia, K ;
Weiland, J ;
Humayun, M ;
Lazzi, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (08) :1469-1477