Detection system for reaction-rate analysis in a low-volume proteinase-inhibition assay

被引:7
作者
Ambrose, WP
Semin, DJ
Robbins, DL
Van Orden, A
Kashem, MA
Hamilton, SA
Nelson, RM
Jett, JH
Keller, RA
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Amgen Inc, Newbury Pk, CA 91320 USA
[3] Amgen Inc, Boulder, CO 80301 USA
关键词
D O I
10.1006/abio.1998.2786
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-throughput screening of large combinatorial chemical libraries in biochemical assays will benefit from reduced reagent volume and increased speed of measurement. Standard assays typically are performed in 96-well microtiter plates having 200-mu L well volumes and up to an hour of incubation time. In this paper, we demonstrate a technique for precise and rapid measurement of the progress of an enzymatic reaction and its inhibition with reduced volume and time (for this work, the assay was mixed at the 200-mu L level and detected in 2-mu L volumes with minutes of total assay time). Directly measuring the enzyme activity in the small volume format yields a precise value for the median inhibitory concentration (IC50) of an inhibitor compound. The model assay is the endoproteolytic cleavage of a small fluorogenic peptide by human neutrophil collagenase (MMP-8). The fluorogenic peptide was labeled at one end with a UV/blue fluorophore (N-methylanthranilyl) and at the other end with a quencher (dinitrophenol). To generate inhibition data, a hydroxamate peptide analog inhibitor of collagenase, actinonin, was included in the reaction. The experiments were performed using ultraviolet laser illumination (325 nm wavelength) and parallel fluorescence detection by a cooled, charge-coupled-device camera system to increase sensitivity and speed. The assay volume was reduced to 2 mu L for data collection, and the total time for mixing incubation, and measurement was less than 6 min. For comparison to a standard format, the same assay was performed in a 96-well microtiter plate in 200 mu L using 30 min of incubation and measurement in a microtiter plate fluorimeter. Median inhibitory concentrations (IC50) for actinonin of 73 +/- 16 and 100 +/- 14 nM were obtained in with assay miniaturization and increases in throughput is a potential loss of precision and accuracy. Laser excitation and parallel detection of fluorescence is a promising approach far increased speed and reduced cost without loss of precision for proteinase inhibition assays. (C) 1998 Academic Press.
引用
收藏
页码:150 / 157
页数:8
相关论文
共 11 条
  • [1] A HIGH-THROUGHPUT FLUOROGENIC SUBSTRATE FOR INTERSTITIAL COLLAGENASE (MMP-1) AND GELATINASE (MMP-9)
    BICKETT, DM
    GREEN, MD
    BERMAN, J
    DEZUBE, M
    HOWE, AS
    BROWN, PJ
    ROTH, JT
    MCGEEHAN, GM
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 212 (01) : 58 - 64
  • [2] Studies on single alkaline phosphatase molecules: Reaction rate and activation energy of a reaction catalyzed by a single molecule and the effect of thermal denaturation - The death of an enzyme
    Craig, DB
    Arriaga, EA
    Wong, JCY
    Lu, H
    Dovichi, NJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (22) : 5245 - 5253
  • [3] Life and death of a single enzyme molecule
    Craig, DB
    Arriaga, E
    Wong, JCY
    Lu, H
    Dovichi, NJ
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (01) : 39A - 43A
  • [4] IMAGING OF SINGLE FLUORESCENT MOLECULES AND INDIVIDUAL ATP TURNOVERS BY SINGLE MYOSIN MOLECULES IN AQUEOUS-SOLUTION
    FUNATSU, T
    HARADA, Y
    TOKUNAGA, M
    SAITO, K
    YANAGIDA, T
    [J]. NATURE, 1995, 374 (6522) : 555 - 559
  • [5] Microchip device for performing enzyme assays
    Hadd, AG
    Raymond, DE
    Halliwell, JW
    Jacobson, SC
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3407 - 3412
  • [6] COOLED SLOW-SCAN CHARGED COUPLED DEVICE IMAGING FLUOROMETER
    HAGGART, R
    [J]. ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) : 48 - 57
  • [7] Characterization of an inkjet chemical microdispenser for combinatorial library synthesis
    Lemmo, AV
    Fisher, JT
    Geysen, HM
    Rose, DJ
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 543 - 551
  • [8] Aminopeptidase profiling using a time-resolved, 96-well plate filter fluorimeter
    Mossman, DM
    Lytle, FE
    Huber, DM
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (10) : 1443 - 1446
  • [10] A high-density screening format for encoded combinatorial libraries: Assay miniaturization and its application to enzymatic reactions
    Schullek, JR
    Butler, JH
    Ni, ZJ
    Chen, D
    Yuan, ZY
    [J]. ANALYTICAL BIOCHEMISTRY, 1997, 246 (01) : 20 - 29