Measurements and simulations of the radiation exposure to aircraft crew workplaces due to cosmic radiation in the atmosphere

被引:13
作者
Beck, P. [1 ]
Latocha, M. [1 ,3 ]
Dorman, L. [2 ]
Pelliccioni, M. [4 ]
Rollet, S. [1 ]
机构
[1] Austrian Res Ctr GmbH, Div Hlth Phys, A-2444 Seibersdorf, Austria
[2] Tel Aviv Univ, Technion Israel Inst Technol, Cosm Ray & Space Weather Ctr, IL-69978 Tel Aviv, Israel
[3] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[4] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Italy
关键词
D O I
10.1093/rpd/ncm114
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As required by the European Directive 96/29/Euratom, radiation exposure due to natural ionizing radiation has to be taken into account at workplaces if the effective dose could become more than 1 mSv per year. An example of workers concerned by this directive is aircraft crew due to cosmic radiation exposure in the atmosphere. Extensive measurement campaigns on board aircrafts have been carried out to assess ambient dose equivalent. A consortium of European dosimetry institutes within EURADOS WG5 summarized experimental data and results of calculations, together with detailed descriptions of the methods for measurements and calculations. The radiation protection quantity of interest is the effective dose, E (ISO). The comparison of results by measurements and calculations is done in terms of the operational quantity ambient dose equivalent, H*(10). This paper gives an overview of the EURADOS Aircraft Crew In-Flight Database and it presents a new empirical model describing fitting functions for this data. Furthermore, it describes numerical simulations performed with the Monte Carlo code FLUKA-2005 using an updated version of the cosmic radiation primary spectra. The ratio between ambient dose equivalent and effective dose at commercial flight altitudes, calculated with FLUKA-2005, is discussed. Finally, it presents the aviation dosimetry model AVIDOS based on FLUKA-2005 simulations for routine dose assessment. The code has been developed by Austrian Research Centers (ARC) for the public usage (http://avidos.healthphysics.at).
引用
收藏
页码:564 / 567
页数:4
相关论文
共 20 条
[1]   Atmospheric neutrino flux above 1 GeV [J].
Agrawal, V ;
Gaisser, TK ;
Lipari, P ;
Stanev, T .
PHYSICAL REVIEW D, 1996, 53 (03) :1314-1323
[2]  
[Anonymous], 2005, CERN2005010
[3]  
Arfken B.G., 1995, MATH METHODS PHYS, VSixth
[4]  
Badhwar G D, 1996, Adv Space Res, V17, P7, DOI 10.1016/0273-1177(95)00507-B
[5]  
BADHWAR GD, 1997, RADIAT RES, V148, P3
[6]  
*BART RES I, NEUTR MON PROGR
[7]  
BATTISTOM G, 2004, PRIMARY COSMIC RAYS
[8]  
*FED AV ADM, CARI6 FED AV ADM
[9]   Calculation of the radiation environment caused by galactic cosmic rays for determining air crew exposure [J].
Ferrari, A ;
Pelliccioni, M ;
Rancati, T .
RADIATION PROTECTION DOSIMETRY, 2001, 93 (02) :101-114
[10]  
Gaisser T., 2001, P 27 INT COSM RAY C