Field tests of correction procedures for turbine flowmeters in pulsatile flows

被引:15
作者
Cheesewright, R
Atkinson, KN
Clark, C
terHorst, GJP
Mottram, RC
Viljeer, J
机构
[1] Dept. of Mfg. and Eng. Systems, Brunel University, Uxbridge
[2] Dept. of Mech. and Mfg. Engineering, University of Brighton
[3] GASTEC NV, 7300 AC Apeldoorn
[4] Department of Mechanical Engineering, University of Surrey, Guildford
关键词
turbine meter over-registration; turbine meter correction procedures; pulsation profiles;
D O I
10.1016/0955-5986(96)00004-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Turbine flowmeters are known to be susceptible to over-registration errors in pulsatile gas flows. The results of applying three possible correction procedures to the outputs from meters installed in Dutch natural gas supply lines are compared. Large amplitude, periodic flow variations were observed both due to pressure regulator oscillations and to irregular gas usage. Errors as high as 60% were observed. Correction procedures assuming sinusoidal pulsation profiles were found to be inappropriate in these flows. Except for intermittent flows, correction to an accuracy of better than +/-2% was found to be possible. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:7 / 17
页数:11
相关论文
共 10 条
[1]  
Atkinson K. N., 1992, Flow Measurement and Instrumentation, V3, P167, DOI 10.1016/0955-5986(92)90032-Z
[2]  
CHEESEWRIGHT R, 1994, P FLUCOME 94 TOULOUS
[3]  
CHEESEWRIGHT R, UNPUB P I MECH E
[4]  
DIJSTELBERGEN HH, 1966, INSTRUM REV, V13, P241
[5]   CURRENTMETER ERRORS UNDER PULSATING FLOW CONDITIONS [J].
JEPSON, P .
JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1967, 9 (01) :45-&
[6]  
MOTTRAM RC, 1985, P IMEKO C FLOW MEAS, P213
[7]  
Ower E, 1926, PHILOS MAG, V2, P881
[8]  
VANMILL CH, 1964, REVUE A, V6, P169
[9]  
VILJEER J, 1994, 19 WORLD GAS C MIL I
[10]  