Target-free Stereo PIV: a novel technique with inherent error estimation and improved accuracy

被引:79
作者
Fouras, Andreas [1 ]
Lo Jacono, David [1 ]
Hourigan, Kerry [1 ]
机构
[1] Monash Univ, FLAIR, Div Biol Engn, Clayton, Vic 3800, Australia
关键词
D O I
10.1007/s00348-007-0404-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A novel, accurate and simple stereo particle image velocimetry (SPIV) technique utilising three cameras is presented. The key feature of the new technique is that there is no need of a separate calibration phase. The calibration data are measured concurrently with the PIV data by a third paraxial camera. This has the benefit of improving ease of use and reducing the time taken to obtain data. This third camera also provides useful velocity information, considerably improving the accuracy of the resolved 3D vectors. The additional redundancy provided by this third perspective in the stereo reconstruction equations suggests a least-squares approach to their solution. The least-squares process further improves the utility of the technique by means of the reconstruction residual. Detailed error analysis shows that this residual is an accurate predictor of resolved vector errors. The new technique is rigorously validated using both pure translation and rotation test cases. However, while this kind of validation is standard, it is shown that such validation is substantially flawed. The case of the well-known confined vortex breakdown flow is offered as an alternative validation. This flow is readily evaluated using CFD methods, allowing a detailed comparison of the data and evaluation of PIV errors in their entirety for this technique.
引用
收藏
页码:317 / 329
页数:13
相关论文
共 26 条
[1]  
[Anonymous], PARTICLE IMAGE VELOC
[2]   STEREOSCOPIC PARTICLE IMAGE VELOCIMETRY [J].
ARROYO, MP ;
GREATED, CA .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) :1181-1186
[3]   Elimination of peak-locking error in PIV analysis using the correlation mapping method [J].
Chen, J ;
Katz, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (08) :1605-1618
[4]   A fluid dynamics approach to bioreactor design for cell and tissue culture [J].
Dusting, Jonathan ;
Sheridan, John ;
Hourigan, Kerry .
BIOTECHNOLOGY AND BIOENGINEERING, 2006, 94 (06) :1196-1208
[5]   OBSERVATIONS OF THE FLOW PRODUCED IN A CYLINDRICAL CONTAINER BY A ROTATING ENDWALL [J].
ESCUDIER, MP .
EXPERIMENTS IN FLUIDS, 1984, 2 (04) :189-196
[6]   Accuracy of out-of-plane vorticity measurements derived from in-plane velocity field data [J].
Fouras, A ;
Soria, J .
EXPERIMENTS IN FLUIDS, 1998, 25 (5-6) :409-430
[7]   A simple calibration technique for stereoscopic particle image velocimetry [J].
Fouras, Andreas ;
Dusting, Jonathan ;
Hourigan, Kerry .
EXPERIMENTS IN FLUIDS, 2007, 42 (05) :799-810
[8]   High-speed scanning stereoscopic PIV for 3D vorticity measurement in liquids [J].
Hori, T ;
Sakakibara, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (06) :1067-1078
[9]   Three-dimensional particle image velocimetry: experimental error analysis of a digital angular stereoscopic system [J].
Lawson, NJ ;
Wu, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (12) :1455-1464
[10]   Stereoscopic micro particle image velocimetry [J].
Lindken, Ralph ;
Westerweel, Jerry ;
Wieneke, Bernhard .
EXPERIMENTS IN FLUIDS, 2006, 41 (02) :161-171