Recombinant human thyrotropin-stimulated serum thyroglobulin combined with neck ultrasonography has the highest sensitivity in monitoring differentiated thyroid carcinoma

被引:289
作者
Pacini, F
Molinaro, E
Castagna, MG
Agate, L
Elisei, R
Ceccarelli, C
Lippi, F
Taddei, D
Grasso, L
Pinchera, A
机构
[1] Univ Pisa, Dept Endocrinol & Metab, Endocrinol Sect, I-56124 Pisa, Italy
[2] Univ Siena, Dept Internal Med, Sect Endocrinol & Metab, I-53100 Siena, Italy
关键词
D O I
10.1210/jc.2002-021925
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recombinant human TSH (rhTSH)-stimulated thyroglobulin (Tg) measurement and (131)I whole body scan (WBS) have been validated as informative tests in the postsurgical follow-up of differentiated thyroid carcinoma. We report the diagnostic accuracy of Tg measurement and diagnostic WBS, alone or in combination, after rhTSH stimulation in a retrospective, consecutive series of patients undergoing follow-up for differentiated thyroid cancer. Routine procedures also include neck ultrasound in every patient and post-therapy WBS when indicated. We studied 340 consecutive patients with differentiated thyroid carcinoma, previously treated with near-total thyroidectomy and (131)I thyroid ablation, scheduled for routine diagnostic tests. At baseline on L-T(4)-suppressive therapy, 294 patients had undetectable (<1 ng/ml) serum Tg and negative anti-Tg autoantibodies (TgAb), 25 patients had undetectable serum Tg and positive TgAb, and 21 patients had detectable serum Tg and negative TgAb. These patients were tested for the presence of active disease by rhTSH stimulation. The results of our study showed that rhTSH-stimulated Tg alone had a diagnostic sensitivity of 85% for detecting active disease and a negative predictive value (NPV) of 98.2%. After adding the results of neck ultrasound, sensitivity increased to 96.3%, and the NPV to 99.5%. rhTSH-stimulated WBS had a sensitivity of only 21% and a NPV of 89%. The combination of rhTSH-stimulated Tg and WBS had a sensitivity of 92.7% and a NPV of 99%. We conclude that the rhTSH-stimulated Tg test combined with neck ultrasonography has the highest diagnostic accuracy in detecting persistent disease in the follow-up of differentiated thyroid carcinoma. A detectable level of serum Tg on L-T(4), its conversion from undetectable to detectable after rhTSH, and/or a suspicious finding at ultrasound will allow the identification of patients requiring therapeutic procedures without the need for diagnostic WBS.
引用
收藏
页码:3668 / 3673
页数:6
相关论文
共 20 条
  • [1] Is diagnostic iodine-131 scanning useful after total thyroid ablation for differentiated thyroid cancer?
    Cailleux, AF
    Baudin, E
    Travagli, JP
    Ricard, M
    Schlumberger, M
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2000, 85 (01) : 175 - 178
  • [2] FeldtRasmussen U, 1996, ANN BIOL CLIN-PARIS, V54, P337
  • [3] Clinical comparison of whole-body radioiodine scan and serum thyroglobulin after stimulation with recombinant human thyrotropin
    Haugen, BR
    Ridgway, EC
    McLaughlin, BA
    McDermott, MT
    [J]. THYROID, 2002, 12 (01) : 37 - 43
  • [4] A comparison of recombinant human thyrotropin and thyroid hormone withdrawal for the detection of thyroid remnant or cancer
    Haugen, BR
    Pacini, F
    Reiners, C
    Schlumberger, M
    Ladenson, PW
    Sherman, SI
    Cooper, DS
    Graham, KE
    Braverman, LE
    Skarulis, MC
    Davies, TF
    DeGroot, LJ
    Mazzaferri, EL
    Daniels, GH
    Ross, DS
    Luster, M
    Samuels, MH
    Becker, DV
    Maxon, HR
    Cavalieri, RR
    Spencer, CA
    McEllin, K
    Weintraub, BD
    Ridgway, EC
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1999, 84 (11) : 3877 - 3885
  • [5] Comparison of administration of recombinant human thyrotropin with withdrawal of thyroid hormone for radioactive iodine scanning in patients with thyroid carcinoma
    Ladenson, PW
    Braverman, LE
    Mazzaferri, EL
    BruckerDavis, F
    Cooper, DS
    Garber, JR
    Wondisford, FE
    Davies, TF
    DeGroot, LJ
    Daniels, GH
    Ross, DS
    Weintraub, BD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (13) : 888 - 896
  • [6] MAIER CA, 1994, J CLIN ENDOCR METAB, V78, P188
  • [7] Is diagnostic iodine-131 scanning with recombinant human TSH useful in the follow-up of differentiated thyroid cancer after thyroid ablation?
    Mazzaferri, EL
    Kloos, RT
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2002, 87 (04) : 1490 - 1498
  • [8] Diagnostic 131-iodine whole-body scan may be avoided in thyroid cancer patients who have undetectable stimulated serum Tg levels after initial treatment
    Pacini, F
    Capezzone, M
    Elisei, R
    Ceccarelli, C
    Taddei, D
    Pinchera, A
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2002, 87 (04) : 1499 - 1501
  • [9] DIAGNOSTIC-VALUE OF A SINGLE SERUM THYROGLOBULIN DETERMINATION ON AND OFF THYROID SUPPRESSIVE THERAPY IN THE FOLLOW-UP OF PATIENTS WITH DIFFERENTIATED THYROID-CANCER
    PACINI, F
    LARI, R
    MAZZEO, S
    GRASSO, L
    TADDEI, D
    PINCHERA, A
    [J]. CLINICAL ENDOCRINOLOGY, 1985, 23 (04) : 405 - 411
  • [10] PACINI F, 1987, J NUCL MED, V28, P1888