Cl-2 gas detection at low temperature using the 0.97PbCl(2)-0.03KCl solid electrolyte prepared by the melting method

被引:7
作者
Aono, H
Yamabayashi, A
Sugimoto, E
Mori, Y
Sadaoka, Y
机构
[1] SUMITOMO MET MIN CO, NIIHAMA RES LABS, NIIHAMA, EHIME 792, JAPAN
[2] EHIME UNIV, FAC ENGN, DEPT MAT SCI & ENGN, MATSUYAMA, EHIME 79077, JAPAN
关键词
D O I
10.1246/cl.1996.689
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A Cl-2 gas sensor with a 0.97PbCl(2)-0.03KCl solid electrolyte and a Pb reference electrode was prepared by a melting method using an evacuated closed tube. The electromotive force (EMF) measured at 573 K agreed with the calculated value for Cl-2 gas concentrations from 10 ppm to 1000 ppm. The response time was long when the operating temperature is lower than 473 K.
引用
收藏
页码:689 / 690
页数:2
相关论文
共 9 条
[1]   CL2 GAS SENSOR USING BACL2-KCL SOLID-ELECTROLYTE PREPARED BY MELTING METHOD [J].
AONO, H ;
SUGIMOTO, E ;
MORI, Y ;
OKAJIMA, Y .
CHEMISTRY LETTERS, 1993, (06) :1039-1042
[2]  
AONO H, 1993, J ELECTROCHEM SOC, V140, P319
[3]  
AONO H, UNPUB SENS ACT
[4]  
Barin I., 1973, THERMOCHEMICAL PROPE
[5]  
NIIZEKI Y, 1986, DENKI KAGAKU, V54, P961
[6]  
NIIZEKI Y, 1986, DENKI KAGAKU, V54, P948
[7]   DESIGN AND TESTING OF A POTENTIOMETRIC CHLORINE GAUGE [J].
PELLOUX, A ;
FABRY, P ;
DURANTE, P .
SENSORS AND ACTUATORS, 1985, 7 (04) :245-252
[8]  
Stull D. R., 1971, JANAF THERMOCHEMICAL
[9]  
TOSHIMA S, 1968, DENKI KAGAKU, V36, P69