Assessment of complications of EUS-guided fine-needle aspiration

被引:253
作者
O'Toole, D
Palazzo, L
Arotçarena, R
Dancour, A
Aubert, A
Hammel, P
Amaris, J
Ruszniewski, P
机构
[1] Hop Beaujon, Gastroenterol Serv, Federat Med Chirurg Heputo Yastroenterol, F-92118 Clichy, France
[2] Clin Louvre, Paris, France
关键词
D O I
10.1067/mge.2001.112839
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: EUS-guided fine-needle aspiration (EUS-FNA) permits both morphologic and cytologic analysis of lesions within or adjacent to the GI tract. Despite increasing use at this technique, the safety and overall complication rates remain poorly defined. Methods: During a period of 20 months, 322 consecutive patients underwent EUS-FNA in 2 centers. All procedures were performed with the patients under general anesthesia. All complications (including local complications resulting from endoscopy/aspiration or clinical complications after the procedure) were evaluated. Potential risk factors for the development of complications were also analyzed including site and nature of the lesion, presence of portal hypertension, and number of needle passes. Results: A total of 345 lesions were aspirated in 322 patients. EUS-FNA involved the pancreas in 248 cases, Pancreatic lesions included solid (134) and cystic (114) types, which required a mean of 2.5 and 1.4 needle passes, respectively. Complications were observed in 4 (1.2%) patients after aspiration of pancreatic cystic lesions (acute pancreatitis, n = 3; aspiration pneumonia, n = l)and all cases of pancreatitis resulted from FNA of lesions in the head/uncinate process. No complications resulted from FNA of solid pancreatic lesions. Complications were not observed after FNA of lymph nodes (n = 62) and one case of aspiration pneumonia was observed after FNA of a stromel tumor, EUS-FNA was performed without complication in 16 patients (5%) with portal hypertension. The number of needle passes was not predictive of complications. Conclusions: Because the overall risk of complications from EUS-FNA was relatively low (1.6%) with no severe or fatal incidents and although the risk appears slightly higher than that for standard EUS alone, the safety of EUS-FNA appears acceptable based on this analysis from an experienced center.
引用
收藏
页码:470 / 474
页数:5
相关论文
共 19 条
[1]   ACUTE-PANCREATITIS - VALUE OF CT IN ESTABLISHING PROGNOSIS [J].
BALTHAZAR, EJ ;
ROBINSON, DL ;
MEGIBOW, AJ ;
RANSON, JHC .
RADIOLOGY, 1990, 174 (02) :331-336
[2]   A comparison of the accuracy of echo features during endoscopic ultrasound (EUS) and EUS-guided fine-needle aspiration for diagnosis of malignant lymph node invasion [J].
Bhutani, MS ;
Hawes, RH ;
Hoffman, BJ .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (06) :474-479
[3]   Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope [J].
Binmoeller, KF ;
Thul, R ;
Rathod, V ;
Henke, P ;
Brand, B ;
Jabusch, HC ;
Soehendra, N .
GASTROINTESTINAL ENDOSCOPY, 1998, 47 (02) :121-127
[4]   Endoscopic ultrasonography: The current status [J].
Brugge, WR .
GASTROENTEROLOGY, 1998, 115 (06) :1577-1583
[5]  
CANARD JM, 1999, GASTROENTEROL CLIN B, V23, pA41
[6]   The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma [J].
Chang, KJ ;
Nguyen, P ;
Erickson, RA ;
Durbin, TE ;
Katz, KD .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (05) :387-393
[7]  
CHANG KJ, 1995, AM J GASTROENTEROL, V90, P148
[8]   COMPLICATIONS OF ULTRASONICALLY GUIDED FINE-NEEDLE ABDOMINAL BIOPSY - RESULTS OF A MULTICENTER ITALIAN STUDY AND REVIEW OF THE LITERATURE [J].
FORNARI, F ;
CIVARDI, G ;
CAVANNA, L ;
DISTASI, M ;
ROSSI, S ;
SBOLLI, G ;
BUSCARINI, L .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1989, 24 (08) :949-955
[9]  
Grandval P, 1999, GASTROEN CLIN BIOL, V23, P566
[10]   Endoscopic ultrasound-guided fine-needle aspiration biopsy using linear array and radial scanning endosonography [J].
Gress, FG ;
Hawes, RH ;
Savides, TJ ;
Ikenberry, SO ;
Lehman, GA .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (03) :243-250