Reliability of elbow stretch reflex assessment in chronic post-stroke hemiparesis

被引:42
作者
Condliffe, EG
Clark, DJ
Patten, C
机构
[1] VA Palo Alto Hlth Care Syst, Rehabil Res & Dev Ctr, Palo Alto, CA 94304 USA
[2] Boston Univ, Neural Control Movement Lab, Dept Rehabil Sci, Boston, MA 02215 USA
[3] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[4] Boston Univ, Dept Rehabil Sci, Boston, MA 02215 USA
[5] Stanford Univ, Sch Med, Dept Orthopaed Surg, Stanford, CA 94305 USA
关键词
reflex; hemiplegia; stroke; reliability; EMG; motor control;
D O I
10.1016/j.clinph.2005.02.030
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To establish reliability of quantitative measures of elbow joint spastic hypertonia in post-stroke hemiparesis. Methods: Nine subjects with post-stroke hemiparesis (mn duration: 42 months) were tested on three separate days. Biceps brachii and brachioradialis EMG were recorded during passive ramp-and-hold extensions applied at seven speeds between 30 and 210 degrees/s. EMG burst duration, onset position threshold, and burst intensity were used to evaluate reflex activity. Torque at 40 degrees of elbow flexion was used as a mechanical indicator of spastic hypertonia. Results: Across speeds ICCs were consistent, means ranged between 0.63 and 0.85. Thus, relative reliability was fair to excellent for all parameters. Absolute reliability, determined using standard error of measurement expressed as a percentage of the mean score (%SEM), improved at higher speeds (>= 120 degrees/s). Conclusions: These results establish reliability of reflex and mechanical measures of elbow spastic hypertonia post-stroke. The data demonstrate greater reflex detection at high speeds, indicating greater potential to document meaningful changes in these distinct aspects of spastic hypertonia following intervention. Significance: Based on findings of this study, reliability was demonstrated using four parameters of reflex EMG and torque indicating measurement consistency across sessions. These observations motivate determination of requisite effect sizes for clinical trials that evaluate treatment outcome. (c) 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1870 / 1878
页数:9
相关论文
共 45 条
[1]
[Anonymous], 1994, PHYS MED REHABIL STA
[2]
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[3]
Altered reflex sensitivity after repeated and prolonged passive muscle stretching [J].
Avela, J ;
Kyröläinen, H ;
Komi, PV .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (04) :1283-1291
[4]
INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[5]
REFLEX ACTIVITY AND MUSCLE TONE DURING ELBOW MOVEMENTS IN PATIENTS WITH SPASTIC PARESIS [J].
DIETZ, V ;
TRIPPEL, M ;
BERGER, W .
ANNALS OF NEUROLOGY, 1991, 30 (06) :767-779
[6]
VOLUNTARY MOVEMENT AT THE ELBOW IN SPASTIC HEMIPARESIS [J].
FELLOWS, SJ ;
KAUS, C ;
THILMANN, AF .
ANNALS OF NEUROLOGY, 1994, 36 (03) :397-407
[7]
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[8]
FUGLMEYER AR, 1975, SCAND J REHABIL MED, V7, P13
[9]
AGONIST AND ANTAGONIST ACTIVITY DURING VOLUNTARY UPPER-LIMB MOVEMENT IN PATIENTS WITH STROKE [J].
GOWLAND, C ;
DEBRUIN, H ;
BASMAJIAN, JV ;
PLEWS, N ;
BURCEA, I .
PHYSICAL THERAPY, 1992, 72 (09) :624-633
[10]
Reliability of measurements of muscle tone and muscle power in stroke patients [J].
Gregson, JM ;
Leathley, MJ ;
Moore, AP ;
Smith, TL ;
Sharma, AK ;
Watkins, CL .
AGE AND AGEING, 2000, 29 (03) :223-228