Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals

被引:241
作者
Farris, Ryan J. [1 ]
Quintero, Hugo A. [1 ]
Goldfarb, Michael [1 ]
机构
[1] Vanderbilt Univ, Nashville, TN 37235 USA
基金
美国国家卫生研究院;
关键词
Assistive technology; lower limb exoskeleton; paraplegia; powered orthosis; spinal cord injured (SCI); RECIPROCATING GAIT ORTHOSIS; SPINAL-CORD-INJURY; EXOSKELETONS; NEUROPROSTHESIS; CHALLENGES; SUPPORT; DESIGN; HGO;
D O I
10.1109/TNSRE.2011.2163083
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
This paper describes a powered lower-limb orthosis that is intended to provide gait assistance to spinal cord injured (SCI) individuals by providing assistive torques at both hip and knee joints. The orthosis has a mass of 12 kg and is capable of providing maximum joint torques of 40 Nm with hip and knee joint ranges of motion from 105 degrees flexion to 30 degrees extension and 105 degrees flexion to 10 degrees hyperextension, respectively. A custom distributed embedded system controls the orthosis with power being provided by a lithium polymer battery which provides power for one hour of continuous walking. In order to demonstrate the ability of the orthosis to assist walking, the orthosis was experimentally implemented on a paraplegic subject with a T10 complete injury. Data collected during walking indicates a high degree of step-to-step repeatability of hip and knee trajectories (as enforced by the orthosis) and an average walking speed of 0.8 km/hr. The electrical power required at each hip and knee joint during gait was approximately 25 and 27 W, respectively, contributing to the 117 W overall electrical power required by the device during walking. A video of walking corresponding to the aforementioned data is included in the supplemental material.
引用
收藏
页码:652 / 659
页数:8
相关论文
共 33 条
[1]
[Anonymous], SPINAL CORD INJURY F
[2]
Gait Evaluation of a Novel Hip Constraint Orthosis With Implication for Walking in Paraplegia [J].
Audu, Musa L. ;
To, Curtis S. ;
Kobetic, Rudi ;
Triolo, Ronald J. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2010, 18 (06) :610-618
[3]
Baardman G, 1997, PROSTHET ORTHOT INT, V21, P210
[4]
BEARD JE, 1991, 2 NAT APPL MECH ROBO
[5]
Energy consumption of paraplegic locomotion using reciprocating gait orthosis [J].
Beillot, J ;
Carre, F ;
LeClaire, G ;
Thoumie, P ;
PerruoinVerbe, B ;
Cormerais, A ;
Courtillon, A ;
Tanguy, E ;
Nadeau, G ;
Rochcongar, P ;
Dassonville, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1996, 73 (3-4) :376-381
[6]
THE EFFICIENCY OF WALKING OF PARAPLEGIC PATIENTS USING A RECIPROCATING GAIT ORTHOSIS [J].
BERNARDI, M ;
CANALE, I ;
CASTELLANO, V ;
DIFILIPPO, L ;
FELICI, F ;
MARCHETTI, M .
PARAPLEGIA, 1995, 33 (07) :409-415
[8]
Brown-Triolo DL, 2002, J REHABIL RES DEV, V39, P659
[9]
BUTLER PB, 1984, PROSTHET ORTHOT INT, V8, P33
[10]
Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art [J].
Dollar, Aaron M. ;
Herr, Hugh .
IEEE TRANSACTIONS ON ROBOTICS, 2008, 24 (01) :144-158