Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm

被引:80
作者
Abdoli, Mehrsima [3 ]
Ay, Mohammad Reza [4 ,5 ,6 ]
Ahmadian, Alireza [4 ,5 ]
Dierckx, Rudi A. J. O. [3 ]
Zaidi, Habib [1 ,2 ,3 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Geneva Neurosci Ctr, CH-1211 Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[4] Univ Tehran Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[5] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[6] Univ Tehran Med Sci, Res Inst Nucl Med, Tehran, Iran
基金
瑞士国家科学基金会;
关键词
PET/CT; attenuation correction; metal artifacts; virtual sinogram; genetic algorithm; COMPUTED-TOMOGRAPHY; IMPLANTS; IMPACT; HEAD;
D O I
10.1118/1.3511507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: The presence of metallic dental fillings is prevalent in head and neck PET/CT imaging and generates bright and dark streaking artifacts in reconstructed CT images. The resulting artifacts would propagate to the corresponding PET images following CT-based attenuation correction (CTAC). This would cause over-and/or underestimation of tracer uptake in corresponding regions thus leading to inaccurate quantification of tracer uptake. The purpose of this study is to improve our recently proposed metal artifact reduction (MAR) approach and to assess its performance in a clinical setting. Methods: The proposed MAR algorithm is performed in the virtual sinogram space to overcome the challenges associated with manipulating raw CT data. The corresponding bins of the virtual sinogram affected by metallic objects are obtained by forward projection of segmented metallic objects in the original CT image. These bins are then substituted by weighted values of three estimates: the affected bins in the original sinogram, the bins in the corrected sinogram using spline interpolation, and the sinogram bins in the neighboring column of the sinogram matrix. The optimized weighting factors (alpha, beta and gamma) were estimated using a genetic algorithm (GA). The optimized combination of weighting coefficients was obtained using the GA applied to 24 clinical CT data sets. The proposed MAR method was then applied to 12 clinical head and neck PET/CT data sets containing dental artifacts. Analysis of the results was performed using Bland and Altman plots and a method allowing analysis in the absence of gold standard called regression without truth (RWT). The proposed method was also compared to an image-based MAR method. Results: Optimization of the weighting coefficients using the GA resulted in an optimum combination of parameters of alpha=0.26, beta=0.67, and gamma=0.07. According to Bland and Altman plots generated for both CT and PET images of the clinical data, the proposed MAR algorithm is efficient for reduction of streak artifacts in CT images and such reduce the over-and/or underestimation of tracer uptake. The RWT method also confirmed the effectiveness of the proposed MAR method. The obtained figures of merit revealed that attenuation corrected PET data corrected using CTAC after applying the MAR algorithm are more similar to the assumed gold standard. Comparison with the knowledge-based method revealed that the proposed method mainly corrects the artifactual regions without modifying the unaffected regions. The knowledge-based method globally modifies the images including those that do not include metallic artifacts. Conclusions: The proposed MAR algorithm improves the quality and quantitative accuracy of clinical head and neck PET/CT images and could be easily integrated in clinical setting. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3511507]
引用
收藏
页码:6166 / 6177
页数:12
相关论文
共 24 条
[1]
Reduction of Dental Filling Metallic Artifacts in CT-Based Attenuation Correction of PET Data Using Weighted Virtual Sinograms [J].
Abdoli, M. ;
Ay, M. R. ;
Ahmadian, A. ;
Zaidi, H. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :2752-+
[2]
A virtual sinogram method to reduce dental metallic implant artefacts in computed tomography-based attenuation correction for PET [J].
Abdoli, Mehrsima ;
Ay, Mohammad Reza ;
Ahmadian, Alireza ;
Zaidi, Habib .
NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (01) :22-31
[3]
Attenuation-emission alignment in cardiac PET/CT based on consistency conditions [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Champley, Kyle M. ;
Caldwell, James H. .
MEDICAL PHYSICS, 2010, 37 (03) :1191-1200
[4]
Correction of CT artifacts and its influence on Monte Carlo dose calculations [J].
Bazalova, Magdalena ;
Beaulieu, Luc ;
Palefsky, Steven ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2007, 34 (06) :2119-2132
[5]
Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants [J].
Goerres, GW ;
Hany, TF ;
Kamel, E ;
von Schulthess, GK ;
Buck, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :367-370
[6]
A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT [J].
Hamill, James J. ;
Brunken, Richard C. ;
Bybel, Bohdan ;
DiFilippo, Frank P. ;
Faul, David D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2901-2918
[7]
Objective comparison of quantitative imaging modalities without the use of a gold standard [J].
Hoppin, JW ;
Kupinski, MA ;
Kastis, GA ;
Clarkson, E ;
Barrett, HH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (05) :441-449
[8]
REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577
[9]
Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner [J].
Kamel, EM ;
Burger, C ;
Buck, A ;
von Schulthess, GK ;
Goerres, GW .
EUROPEAN RADIOLOGY, 2003, 13 (04) :724-728
[10]
The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners [J].
Kennedy, John A. ;
Israel, Ora ;
Frenkel, Alex ;
Bar-Shalom, Rachel ;
Azhari, Haim .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (06) :553-562