Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-Sensors, and enzyme biosensors

被引:1142
作者
Katz, E [1 ]
Willner, I [1 ]
机构
[1] Hebrew Univ Jerusalem, Inst Chem, IL-91904 Jerusalem, Israel
关键词
impedance spectroscopy; biosensor; immunosensor; DNA sensor; enzyme; field-effect transistor; capacitance; bioelectronics;
D O I
10.1002/elan.200390114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Impedance spectroscopy is a rapidly developing electrochemical technique for the characterization of biomaterial-functionalized electrodes and biocatalytic transformations at electrode surfaces, and specifically for the transduction of biosensing events at electrodes or field-effect transistor devices. The immobilization of biomaterials, e.g., enzymes, antigens/antibodies or DNA on electrodes or semiconductor surfaces alters the capacitance and interfacial electron transfer resistance of the conductive or semiconductive electrodes. Impedance spectroscopy allows analysis of interfacial changes originating from biorecognition events at electrode surfaces. Kinetics and mechanisms of electron transfer processes corresponding to biocatalytic reactions occurring at modified electrodes can be also derived from Faradaic impedance spectroscopy. Different immunosensors that use impedance measurements for the transduction of antigen-antibody complex formation on electronic transducers were developed. Similarly, DNA biosensors using impedance measurements as readout signals were developed. Amplified detection of the analyte DNA using Faradaic impedance spectroscopy was accomplished by the coupling of functionalized liposomes or by the association of biocatalytic conjugates to the sensing interface providing biocatalyzed precipitation of an insoluble product on the electrodes. The amplified detections of viral DNA and single-base mismatches in DNA were accomplished by similar methods. The changes of interfacial features of gate surfaces of field-effect transistors (FET) upon the formation of antigen-antibody complexes or assembly of protein arrays were probed by impedance measurements and specifically by transconductance measurements. Impedance spectroscopy was also applied to characterize enzyme-based biosensors. The reconstitution of apo-enzymes on cofactor-functionalized electrodes and the formation of cofactor-enzyme affinity complexes on electrodes were probed by Faradaic impedance spectroscopy. Also biocatalyzed reactions occurring on electrode surfaces were analyzed by impedance spectroscopy. The theoretical background of the different methods and their practical applications in analytical procedures were outlined in this article.
引用
收藏
页码:913 / 947
页数:35
相关论文
共 189 条
  • [1] Cell-based biosensors for inflammatory agents detection
    Abdelghani, A
    Abdelghani-Jacquin, C
    Hillebrandt, H
    Sackmann, E
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2002, 22 (01): : 67 - 72
  • [2] Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes
    Alfonta, L
    Willner, I
    Throckmorton, DJ
    Singh, AK
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5287 - 5295
  • [3] Liposomes labeled with biotin and horseradish peroxidase: A probe for the enhanced amplification of antigen-antibody or oligonucleotide-DNA sensing processes by the precipitation of an insoluble product on electrodes
    Alfonta, L
    Singh, AK
    Willner, I
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (01) : 91 - 102
  • [4] Sensing of acetylcholine by a tricomponent-enzyme layered electrode using faradaic impedance spectroscopy, cyclic voltammetry, and microgravimetric quartz crystal microbalance transduction methods
    Alfonta, L
    Katz, E
    Willner, I
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (05) : 927 - 935
  • [5] Chronopotentiometry and Faradaic impedance spectroscopy as signal transduction methods for the biocatalytic precipitation of an insoluble product on electrode supports: routes for enzyme sensors, immunosensors and DNA sensors
    Alfonta, L
    Bardea, A
    Khersonsky, O
    Katz, E
    Willner, I
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) : 675 - 687
  • [6] Electronic transduction of biocatalytic transformations on nucleic acid-functionalized surfaces
    Alfonta, L
    Willner, I
    [J]. CHEMICAL COMMUNICATIONS, 2001, (16) : 1492 - 1493
  • [7] USE OF SELF-ASSEMBLED MONOLAYERS TO COVALENTLY TETHER PROTEIN MONOLAYERS TO THE SURFACE OF SOLID SUBSTRATES
    AMADOR, SM
    PACHENCE, JM
    FISCHETTI, R
    MCCAULEY, JP
    SMITH, AB
    BLASIE, JK
    [J]. LANGMUIR, 1993, 9 (03) : 812 - 817
  • [8] Sensitive immunodetection through impedance measurements onto gold functionalized electrodes
    Ameur, S
    Martelet, C
    Jaffrezic-Renault, N
    Chovelon, JM
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 161 - 170
  • [9] Membrane characterization of anion-selective CHEMFETs by impedance spectroscopy
    Antonisse, MMG
    Snellink-Ruël, BHM
    Lugtenberg, RJW
    Engbersen, JFJ
    van den Berg, A
    Reinhoudt, DN
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (02) : 343 - 348
  • [10] Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: Elimination of ascorbate interference by means of an ascorbate oxidase multilayer
    Anzai, J
    Takeshita, H
    Kobayashi, Y
    Osa, T
    Hoshi, T
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (04) : 811 - 817