Application of an [18F] fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy

被引:50
作者
Essner, R
Hsueh, EC
Haigh, PI
Glass, EC
Huynh, Y
Daghighian, F
机构
[1] John Wayne Canc Inst, Roy E Coats Res Labs, Santa Monica, CA 90404 USA
[2] St Johns Hlth Ctr, Dept Nucl Med, Santa Monica, CA 90404 USA
[3] IntraMed Imaging Inc, Los Angeles, CA 90025 USA
关键词
F-18]fluorodeoxyglucose; positron emission tomography; gamma probe;
D O I
10.1006/jsre.2000.6069
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Whole-body positron emission tomography (PET) has been shown to be a highly sensitive method for detecting malignancy not imaged by conventional modalities. We have adapted a hand-held gamma -ray-sensitive probe to detect the radiation emission from the [F-18]fluorodeoxyglucose (FDG) used in PET imaging. This pilot study was devised to examine the feasibility of using a hand-held probe to intraoperatively differentiate normal from tumor-bearing tissue. Materials and methods. A commercially available gamma probe was adapted to detect the radioactivity released from FDG and examined to determine the in vitro sensitivity for localization of a FDG point source. Eight consecutive patients underwent resection of metastatic colon cancer or melanoma; each received a preoperative injection of 7-10 mCi of FDG. The gamma probe was used to determine radioactive counts per second from tumor and normal tissue, and ratios of tumor to adjacent normal background were calculated. Results. In vitro studies with a FDG point source demonstrated the probe could identify the source with a 50% reduction in maximum counts 1.7 +/- 0.1 cm from the source (full-width half-maximum measurement). Based on the results of their preoperative PET scans 17 tumors were identified from the 8 patients. Of the 17 tumors assessed the in vivo tumor-to-background ratios varied from 1.16:1 to 4.67:1 for the melanoma patients (13 tumors) and from 1.19:1 to 7.92:1 for colon cancer patients (4 tumors). Thirteen tumors were resected; four (2 patients) were unresectable. Conclusions. This study demonstrates the use of a hand-held gamma -ray-sensitive probe to intraoperatively differentiate the radioactivity released from FDG from tumor-bearing and adjacent normal tissue. While further studies are necessary for us to optimize the use of this probe, the intraoperative detection of FDG-avid malignancies may ultimately improve our ability to completely resect patients with metastatic disease. (C) 2001 Academic Press.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 43 条
[1]   Radioimmunoguided surgery for patients with liver metastases secondary to colorectal cancer [J].
Bakalakos, EA ;
Young, DC ;
Martin, EW .
ANNALS OF SURGICAL ONCOLOGY, 1998, 5 (07) :590-594
[2]   Radioimmunoguided surgery for colorectal cancer [J].
Bertsch, DJ ;
Burak, WE ;
Young, DC ;
Arnold, MW ;
Martin, WE .
ANNALS OF SURGICAL ONCOLOGY, 1996, 3 (03) :310-316
[3]   Sentinel lymph node biopsy in breast cancer: Guidelines and pitfalls of lymphoscintigraphy and gamma probe detection [J].
Borgstein, P ;
Pijpers, R ;
Comans, EF ;
van Diest, PJ ;
Boom, RP ;
Meijer, S .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (03) :275-283
[4]  
BOUTIN C, 1993, CANCER, V72, P389, DOI 10.1002/1097-0142(19930715)72:2<389::AID-CNCR2820720213>3.0.CO
[5]  
2-V
[6]  
Brandau W, 1996, J NUCL MED, V37, P1865
[7]  
CHANDRA R, 1992, INTRO PHYSICS NUCL M
[8]  
Chen E M, 1997, Diagn Imaging (San Franc), V19, P61
[9]   INTRAOPERATIVE BETA-PROBE - A DEVICE FOR DETECTING TISSUE LABELED WITH POSITRON OR ELECTRON EMITTING ISOTOPES DURING SURGERY [J].
DAGHIGHIAN, F ;
MAZZIOTTA, JC ;
HOFFMAN, EJ ;
SHENDEROV, P ;
ESHAGHIAN, B ;
SIEGEL, S ;
PHELPS, ME .
MEDICAL PHYSICS, 1994, 21 (01) :153-157
[10]  
DAMIAN DL, 1996, MELANOMA RES, V6, P375