Reconstructed measurements produced from ultrasound images using a computerized system

被引:3
作者
Herman, A [1 ]
Abargel, A
Maymon, R
Dreazen, E
Tovbin, Y
Weinraub, Z
机构
[1] Assaf Harofeh Med Ctr, Dept Obstet & Gynecol, IL-70300 Zerifin, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
reconstructed measurements; ultrasound image; computer system;
D O I
10.1046/j.1469-0705.2001.00308.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective The aim of this study was to evaluate the feasibility and accuracy of reconstructed measurements produced from video-printed ultrasound images. Design Reproduction of reconstructed measurements using designated software and comparison of the results with regular measurements derived from the same images. Subjects Seventy regular sonographic examinations of biparietal diameter (BPD) and nuchal translucency (NT) thickness. Methods The study included 35 conventional-size (BPD) and 35 small-size (NT) measurements. Each image was measured twice during a dynamic ultrasound examination (regular measurements) and twice using a computerized system (reconstructed measurements). The latter comprised three steps: (i) computerization (computer-generated images by scanning); (ii) calibration (using the scale located alongside the image); (iii) measurement (placing the calipers at the desired points). Results All images were successfully scanned, and the computer-generated images were of sufficient quality for proper measurement. There was no difference between mean values of regular and reconstructed BPD measurements, 63.9 mm (3.7 mm, SE) and 63.6 mm (3.8 mm, SE), respectively. Similarly, mean values of regular NT measurements were similar to the reconstructed ones, 1.48 mm (0.09 mm, SE) and 1.49 mm (0.09 mm, SE), respectively. Repeated regular BPD and NT measurements exhibited repeatability coefficients of 1.6 mm and 0.4 mm, respectively. These values were smaller than those obtained by repeated reconstructed measurements of 2.1 mm and 0.52 mm, respectively. Conclusions Reconstructed measurements of ultrasound video-printed images are feasible, require modest facilities and exhibit more than reasonable accuracy. This option may contribute to medical research, audit, quality control and training, as well as to medico-legal issues.
引用
收藏
页码:54 / 57
页数:4
相关论文
共 10 条
[1]  
CAMPBELL S, 1968, Journal of Obstetrics and Gynaecology of the British Commonwealth, V75, P568
[2]   ULTRASONIC MEASUREMENT OF FETAL ABDOMEN CIRCUMFERENCE IN ESTIMATION OF FETAL WEIGHT [J].
CAMPBELL, S ;
WILKIN, D .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1975, 82 (09) :689-697
[3]  
DONALD I, 1958, LANCET, V1, P1188
[4]   FETAL ABDOMINAL CIRCUMFERENCE AS A PREDICTOR OF MENSTRUAL AGE [J].
HADLOCK, FP ;
DETER, RL ;
HARRIST, RB ;
PARK, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (02) :367-370
[5]   FETAL HEAD CIRCUMFERENCE - RELATION TO MENSTRUAL AGE [J].
HADLOCK, FP ;
DETER, RL ;
HARRIST, RB ;
PARK, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (04) :649-653
[6]   FETAL NUCHAL TRANSLUCENCY - ULTRASOUND SCREENING FOR CHROMOSOMAL DEFECTS IN 1ST TRIMESTER OF PREGNANCY [J].
NICOLAIDES, KH ;
AZAR, G ;
BYRNE, D ;
MANSUR, C ;
MARKS, K .
BRITISH MEDICAL JOURNAL, 1992, 304 (6831) :867-869
[7]   ASSESSMENT OF GESTATIONAL-AGE IN THE 2ND TRIMESTER BY REAL-TIME ULTRASOUND MEASUREMENT OF THE FEMUR LENGTH [J].
OBRIEN, GD ;
QUEENAN, JT ;
CAMPBELL, S .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 139 (05) :540-545
[8]   REPEATABILITY OF MEASUREMENT OF FETAL NUCHAL TRANSLUCENCY THICKNESS [J].
PANDYA, PP ;
ALTMAN, DG ;
BRIZOT, ML ;
PETTERSEN, H ;
NICOLAIDES, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (05) :334-337
[9]   SONAR MEASUREMENT OF FETAL CROWN-RUMP LENGTH AS MEANS OF ASSESSING MATURITY IN FIRST TRIMESTER OF PREGNANCY [J].
ROBINSON, HP .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 4 (5883) :28-31
[10]  
WILLOCKS J, 1964, J OBSTET GYN BR COMM, V71, P11