First-pass whole-body magnetic resonance angiography (MRA) using the blood-pool contrast medium gadofosveset trisodium - Comparison to gadopentetate dimeglumine

被引:57
作者
Klessen, Christian
Hein, Patrick A.
Huppertz, Alexander
Voth, Matthias
Wagner, Moritz
Elgeti, Thomas
Kroll, Hannes
Hamm, Bernd
Taupitz, Matthias
Asbach, Patrick
机构
[1] Univ Med Berlin, Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Charite Berlin Siemens, Imaging Sci Inst, D-10115 Berlin, Germany
[3] Bayer Schering Pharma AG, D-13342 Berlin, Germany
关键词
magnetic resonance imaging; magnetic resonance; angiography; contrast media; blood pool contrast media; clinical studies;
D O I
10.1097/RLI.0b013e318063c635
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate gadofosveset trisodium for first-pass magnetic resonance angiography (MRA) in the setting of whole-body MRA (WB-MRA). Materials and Methods: Forty patients were examined using either 10 mL gadofosveset trisodium (n = 20) or 30 mL gadopentetate dimeglumine (n = 20), followed by arterial-phase imaging of 4 consecutive anatomic regions. Signal intensity was measured in 2 vessels per region. Relative contrast values (RC) were calculated. Arterial contrast, venous overlay, and image quality were rated by 2 radiologists. The Mann-Whitney U test was used to test for significance. Results: Compared with gadopentetate dimeglumine, gadofosveset trisodium enhanced imaging revealed higher RC values in 2 vessel regions, with the differences being significant in 3 of 4 vessel segments. Gadofosveset trisodium revealed lower RC values in 2 regions with significant differences in 2 segments. Qualitative evaluation revealed higher ratings for gadofosveset trisodium regarding all 3 criteria with significant differences in 2 regions. Conclusions: Gadofosveset trisodium serves well for first-pass imaging in WB-MRA.
引用
收藏
页码:659 / 664
页数:6
相关论文
共 26 条
[1]   Grading of carotid artery stenosis using high resolution dynamic magnetic resonance angiography in comparison to intraarterial digital subtraction angiography. Are stenoses over 70% reliably detectable? [J].
Aschenbach, R ;
Eger, C ;
Basche, S ;
Vogl, TJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (03) :357-362
[2]   Carotid MR angiography: Phase II study of safety and efficacy for MS-325 [J].
Bluemke, DA ;
Stillman, AE ;
Bis, KG ;
Grist, TM ;
Baum, RA ;
D'Agostino, R ;
Malden, ES ;
Pierro, JA ;
Yucel, EK .
RADIOLOGY, 2001, 219 (01) :114-122
[3]  
Borisch I, 2003, AM J NEURORADIOL, V24, P1117
[4]   Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography [J].
De Cobelli, F ;
Venturini, M ;
Vanzulli, A ;
Sironi, S ;
Salvioni, M ;
Angeli, E ;
Scifo, P ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
Del Maschio, A .
RADIOLOGY, 2000, 214 (02) :373-380
[5]  
Dormandy J, 1999, Semin Vasc Surg, V12, P118
[6]   MR angiography of aortoiliac occlusive disease: A phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325 [J].
Goyen, M ;
Edelman, M ;
Perreault, P ;
O'Riordan, E ;
Bertoni, H ;
Taylor, J ;
Siragusa, D ;
Sharafuddin, M ;
Mohler, ER ;
Breger, R ;
Yucel, EK ;
Shamsi, K ;
Weisskoff, RM .
RADIOLOGY, 2005, 236 (03) :825-833
[7]   Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography [J].
Goyen, M ;
Herborn, CU ;
Lauenstein, TC ;
Barkhausen, J ;
Veit, P ;
Bosk, S ;
Debatin, JF ;
Ruehm, SG .
INVESTIGATIVE RADIOLOGY, 2002, 37 (05) :263-268
[8]   Whole-body three-dimensional MR angiography with a rolling table platform:: Initial clinical experience [J].
Goyen, M ;
Quick, HH ;
Debatin, JF ;
Ladd, ME ;
Barkhausen, J ;
Herborn, CU ;
Bosk, S ;
Kuehl, H ;
Schlepütz, M ;
Ruehm, SG .
RADIOLOGY, 2002, 224 (01) :270-277
[9]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[10]   Initial imaging recommendations for Wasovist angiography [J].
Hartmann, M ;
Wiethoff, AJ ;
Hentrich, HR ;
Rohrer, M .
EUROPEAN RADIOLOGY, 2006, 16 :B15-B23