Long term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias

被引:57
作者
Tavernier, R [1 ]
Gevaert, S [1 ]
De Sutter, J [1 ]
De Clercq, A [1 ]
Rottiers, H [1 ]
Jordaens, L [1 ]
Fonteyne, W [1 ]
机构
[1] State Univ Ghent Hosp, Dept Cardiol, B-9000 Ghent, Belgium
关键词
arrhythmogenic right ventricular dysplasia; implantable cardioverter defibrillator; arrhythmia;
D O I
10.1136/heart.85.1.53
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To study the outcome of patients with arrhythmogenic right ventricular dysplasia treated with an implantable cardioverter-defibrillator (ICD) for ventricular tachyarrhythmias complicated by haemodynamic collapse. Design-Observational study. Setting-University hospital. Patients-Nine consecutive patients (eight male, one female; mean (SD) age, 36 (18) years) with arrhythmogenic right ventricular dysplasia presenting with ventricular tachycardia and haemodynamic collapse (n = 6) or ventricular fibrillation (n = 3), treated with an ICD. Main outcome measures-Survival; numbers of and reasons for appropriate and inappropriate ICD interventions. Results-After a mean (SD) follow up of 32 (24) months, all patients were alive. Six patients received a median of 19 (range 2-306) appropriate ICD interventions for events detected in the ventricular tachycardia window; four received a median of 2 (range 1-19) appropriate ICD interventions for events detected in the ventricular fibrillation window. Inappropriate interventions were seen for sinus tachycardia (18 episodes in three patients), atrial fibrillation (three episodes in one patient), and for non-sustained polymorphic ventricular tachycardia tone episode in one patient). Conclusions-Patients with arrhythmogenic right ventricular dysplasia and malignant ventricular arrhythmias have a high recurrence rate requiring appropriate ICD interventions, but they also often have inappropriate interventions. Programming the device is difficult because this population develops supraventricular and ventricular tachyarrhythmias with similar rates.
引用
收藏
页码:53 / 56
页数:4
相关论文
共 10 条
[1]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN PATIENTS WITH ARRHYTHMOGENIC RIGHT-VENTRICULAR CARDIOMYOPATHY, LONG QT SYNDROME, OR NO STRUCTURAL HEART-DISEASE [J].
BREITHARDT, G ;
WICHTER, T ;
HAVERKAMP, W ;
BORGGREFE, M ;
BLOCK, M ;
HAMMEL, D ;
SCHELD, HH .
AMERICAN HEART JOURNAL, 1994, 127 (04) :1151-1158
[2]   Enhanced detection criteria in implantable defibrillators [J].
Brugada, J ;
Mont, L ;
Figueiredo, M ;
Valentino, M ;
Matas, M ;
Navarro-López, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (03) :261-268
[3]  
FONTAINE G, 2000, CARDIAC ELECTROPHYSI, P546
[4]   Arrhythmogenic Right Ventricular Dysplasia: Clinical Results with Implantable Cardioverter Defibrillators [J].
Link M.S. ;
Wang P.J. ;
Haugh C.J. ;
Homoud M.K. ;
Foote C.B. ;
Costeas X.B. ;
Estes III N.A.M. .
Journal of Interventional Cardiac Electrophysiology, 1997, 1 (1) :41-48
[5]  
MCKENNA WJ, 1994, BRIT HEART J, V71, P218
[6]   LONG-TERM EVOLUTION OF RIGHT-VENTRICULAR DYSPLASIA CARDIOMYOPATHY [J].
PINAMONTI, B ;
DILENARDA, A ;
SINAGRA, G ;
SILVESTRI, F ;
BUSSANI, R ;
CAMERINI, F ;
ALBERTI, E ;
LARDIERI, G ;
MORGERA, T ;
PERKAN, A ;
RAKAR, S ;
SALVI, A ;
ZECCHIN, M ;
GIACCA, M ;
MESTRONI, L ;
SEVERINI, G ;
FALASCHI, A ;
TANGANELLI, P .
AMERICAN HEART JOURNAL, 1995, 129 (02) :412-415
[7]  
SADOUL N, 1999, PACE, V22, P125
[8]   DISCRIMINATION OF VENTRICULAR-TACHYCARDIA FROM SINUS TACHYCARDIA AND ATRIAL-FIBRILLATION IN A TIERED-THERAPY CARDIOVERTER-DEFIBRILLATOR [J].
SWERDLOW, CD ;
CHEN, PS ;
KASS, RM ;
ALLARD, JR ;
PETER, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) :1342-1355
[9]  
TAVERNIER R, 1997, CARDIAC ARRHYTHMIAS, P33
[10]   EFFICACY OF ANTIARRHYTHMIC DRUGS IN PATIENTS WITH ARRHYTHMOGENIC RIGHT VENTRICULAR DISEASE - RESULTS IN PATIENTS WITH INDUCIBLE AND NONINDUCIBLE VENTRICULAR-TACHYCARDIA [J].
WICHTER, T ;
BORGGREFE, M ;
HAVERKAMP, W ;
XU, C ;
BREITHARDT, G .
CIRCULATION, 1992, 86 (01) :29-37