Mechanisms for discordant alternans

被引:287
作者
Watanabe, MA
Fenton, FH
Evans, SJ
Hastings, HM
Karma, A
机构
[1] Northeastern Univ, Dept Phys, Boston, MA 02115 USA
[2] Hofstra Univ, Dept Math, Hempstead, NY 11550 USA
[3] Beth Israel Hosp, Dept Cardiol, New York, NY USA
关键词
discordant alternans; T wave alternans; dynamic restitution; restitution;
D O I
10.1046/j.1540-8167.2001.00196.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Discordant Altelrnans Mechanism. Introduction: Discordant alternans has the potential to produce larger alternans of the ECG T wave than concordant alternans, but its mechanism is unknown. Methods and Results: We demonstrate by one- and two-dimensional simulation of action potential propagation models that discordant alternans can form spontaneously in spatially homogeneous tissue through one of two mechanisms, due to the interaction of conduction velocity and action potential duration restitution at high pacing frequencies or through the dispersion of diastolic interval produced by ectopic foci. In discordant alternans due to the first mechanism, the boundaries marking regions of alternans with opposite phase arise far from the stimulus site, move toward the stimulus site, and stabilize. Dynamic splitting of action potential duration restitution curves due to electrotonic coupling plays a crucial role in this stability. Larger tissues and faster pacing rates are conducive to multiple boundaries, and inhomogeneities of tissue properties facilitate or inhibit formation of boundaries. Conclusion: Spatial inhomogeneities of electrical restitution properties are not required to produce discordant alternans.
引用
收藏
页码:196 / 206
页数:11
相关论文
共 33 条
[1]   RECONSTRUCTION OF ACTION POTENTIAL OF VENTRICULAR MYOCARDIAL FIBERS [J].
BEELER, GW ;
REUTER, H .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 268 (01) :177-210
[2]   Spatiotemporal heterogeneity in the induction of ventricular fibrillation by rapid pacing importance of cardiac restitution properties [J].
Cao, JM ;
Qu, ZL ;
Kim, YH ;
Wu, TJ ;
Garfinkel, A ;
Weiss, JN ;
Karagueuzian, HS ;
Chen, PS .
CIRCULATION RESEARCH, 1999, 84 (11) :1318-1331
[3]   INSTABILITIES OF A PROPAGATING PULSE IN A RING OF EXCITABLE MEDIA [J].
COURTEMANCHE, M ;
GLASS, L ;
KEENER, JP .
PHYSICAL REVIEW LETTERS, 1993, 70 (14) :2182-2185
[4]   ELECTROPHYSIOLOGICAL ALTERNANS AND RESTITUTION DURING ACUTE REGIONAL ISCHEMIA IN MYOCARDIUM OF ANESTHETIZED PIG [J].
DILLY, SG ;
LAB, MJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1988, 402 :315-333
[5]   EFFECT OF ACUTE CORONARY-ARTERY OCCLUSION ON SUB-EPICARDIAL TRANSMEMBRANE POTENTIALS IN INTACT PORCINE HEART [J].
DOWNAR, E ;
JANSE, MJ ;
DURRER, D .
CIRCULATION, 1977, 56 (02) :217-224
[6]   Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias [J].
Estes, NAM ;
Michaud, G ;
Zipes, DP ;
ElSherif, N ;
Venditti, FJ ;
Rosenbaum, DS ;
Albrecht, P ;
Wang, PJ ;
Cohen, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1314-1318
[7]   Vortex dynamics in three-dimensional continuous myocardium with fiber rotation: Filament instability and fibrillation [J].
Fenton, F ;
Karma, A .
CHAOS, 1998, 8 (01) :20-47
[8]   Memory in an excitable medium: A mechanism for spiral wave breakup in the low-excitability limit [J].
Fenton, FH ;
Evans, SJ ;
Hastings, HM .
PHYSICAL REVIEW LETTERS, 1999, 83 (19) :3964-3967
[9]   Preventing ventricular fibrillation by flattening cardiac restitution [J].
Garfinkel, A ;
Kim, YH ;
Voroshilovsky, O ;
Qu, ZL ;
Kil, JR ;
Lee, MH ;
Karagueuzian, HS ;
Weiss, JN ;
Chen, PS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (11) :6061-6066
[10]  
Guevara M. R., 1984, Computers in Cardiology (Cat. No. 84CH2078-4), P167