Microfluidic capillary system for immunoaffinity separations of C-reactive protein in human serum and cerebrospinal fluid

被引:29
作者
Peoples, Michael C. [1 ]
Karnes, H. Thomas [1 ]
机构
[1] Virginia Commonwealth Univ, Med Ctr, Dept Pharmaceut, Richmond, VA 23298 USA
关键词
D O I
10.1021/ac800244n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized system based on microfluidic capillaries is presented for point-of-care testing and clinical assessment. The approach relies on microsyringe pump-generated flow to deliver reagents and immunoaffinity chromatography to isolate the antigen from biological matrixes. Capillary sandwich immunoassays for C-reactive protein (CRP) were demonstrated in human serum and cerebrospinal fluid (CSF), which are relevant matrixes for cardiovascular disease risk and meningitis research, respectively. Capillaries packed with antibody-coated silica beads were used to capture CRP from the matrix and a second, dye-labeled antibody was introduced to form a sandwich complex. An acidic elution buffer dissociated the antibody-antigen complexes, and the labeled antibody was detected with diode laser-induced fluorescence. Four parameter logistic functions and % relative error plots were used to model and assess the data. The calibration ranges for CRP were 0.05-3.0 mu g/mL in 1:10 diluted serum and 0.01-30 mu g/mL in undiluted CSF. The microfluidic apparatus employed a flow rate of 2 mu L/min and a sample injection volume of 250 nL. Since it was not necessary to reach antibody-antigen reaction equilibrium and the assay platform dimensions were minimal, run times were as short as 10 min.
引用
收藏
页码:3853 / 3858
页数:6
相关论文
共 38 条
[1]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[2]   Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples [J].
Bhattacharyya, A. ;
Klapperich, C. M. .
BIOMEDICAL MICRODEVICES, 2007, 9 (02) :245-251
[3]   Application of microchip assay system for the measurement of C-reactive protein in human saliva [J].
Christodoulides, N ;
Mohanty, S ;
Miller, CS ;
Langub, MC ;
Floriano, PN ;
Dharshan, P ;
Ali, MF ;
Bernard, B ;
Romanovicz, D ;
Anslyn, E ;
Fox, PC ;
McDevitt, JT .
LAB ON A CHIP, 2005, 5 (03) :261-269
[4]   Sequential affinity chromatography miniaturized within a "lab-on-valve'' system [J].
Erxleben, H ;
Ruzicka, J .
ANALYST, 2005, 130 (04) :469-471
[5]   Appropriate calibration curve fitting in ligand binding assays [J].
Findlay, John W. A. ;
Dillard, Robert F. .
AAPS JOURNAL, 2007, 9 (02) :E260-E267
[6]   CHANGES IN INTRACRANIAL CSF VOLUME AFTER LUMBAR PUNCTURE AND THEIR RELATIONSHIP TO POST-LP HEADACHE [J].
GRANT, R ;
CONDON, B ;
HART, I ;
TEASDALE, GM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1991, 54 (05) :440-442
[7]   HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY AND CHEMILUMINESCENT DETECTION IN THE AUTOMATION OF A PARATHYROID-HORMONE SANDWICH IMMUNOASSAY [J].
HAGE, DS ;
KAO, PC .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :586-595
[8]   Immunoassay on a power-free microchip with Laminar flow-assisted dendritic amplification [J].
Hosokawa, Kazuo ;
Omata, Masaki ;
Maeda, Mizuo .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :6000-6004
[9]   High-sensitivity C-reactive protein levels in cerebrospinal fluid and serum in severe head injury:: Relationship to tumor necrosis factor-α and interleukin-6 [J].
Is, Merih ;
Coskun, Abdurrahman ;
Sanus, Galip Zihni ;
Tanriverdi, Taner ;
Kafadar, Ali Metin ;
Hanimoglu, Hakan ;
Tanriover, Necmettin ;
Gezen, Ferruh ;
Uzan, Mustafa .
JOURNAL OF CLINICAL NEUROSCIENCE, 2007, 14 (12) :1163-1171
[10]   Enzyme-linked immunosorbent assays in a chromatographic format [J].
Johns, MA ;
Rosengarten, LK ;
Jackson, M ;
Regnier, FE .
JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (01) :195-206