Simultaneous reconstruction of absorption and scattering maps with ultrasound localization: feasibility study using transmission geometry

被引:22
作者
Huang, MM [1 ]
Xie, TQ [1 ]
Chen, NG [1 ]
Zhu, Q [1 ]
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
关键词
D O I
10.1364/AO.42.004102
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the experimental results of the simultaneous reconstruction of absorption and scattering coefficient maps with ultrasound localization. Near-infrared (NIR) data were obtained from frequency domain and dc systems with source and detector fibers configured in transmission geometry. High- or low-contrast targets located close to either the boundary or the center of the turbid medium were reconstructed by using NIR data only and NIR data with ultrasound localization. Results show that the mean reconstructed absorption coefficient and the spatial distribution of the absorption map have been improved significantly with ultrasound localization. The improvements in the mean scattering coefficient and the spatial distribution of the scattering coefficient are moderate. When both the absorption and the scattering coefficients are reconstructed the performance of the frequency-domain system is much better than that of the dc system. (C) 2003 Optical Society of America.
引用
收藏
页码:4102 / 4114
页数:13
相关论文
共 25 条
[1]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .2. FINITE-ELEMENT-METHOD CALCULATIONS [J].
ARRIDGE, SR ;
SCHWEIGER, M .
APPLIED OPTICS, 1995, 34 (34) :8026-8037
[2]   Imaging the body with diffuse optical tomography [J].
Boas, DA ;
Brooks, DH ;
Miller, EL ;
DiMarzio, CA ;
Kilmer, M ;
Gaudette, RJ ;
Zhang, Q .
IEEE SIGNAL PROCESSING MAGAZINE, 2001, 18 (06) :57-75
[3]  
CHANCE B, 2002, DIG TOP M BIOM OPT S, P450
[4]   Monte Carlo approach to modeling of boundary conditions for the diffusion equation [J].
Chen, NG ;
Bai, J .
PHYSICAL REVIEW LETTERS, 1998, 80 (24) :5321-5324
[5]   Characterization of small absorbers inside turbid media [J].
Chen, NG ;
Zhu, QI .
OPTICS LETTERS, 2002, 27 (04) :252-254
[6]   Simultaneous near-infrared diffusive light and ultrasound imaging [J].
Chen, NG ;
Guo, PY ;
Yan, SK ;
Piao, DQ ;
Zhu, Q .
APPLIED OPTICS, 2001, 40 (34) :6367-6380
[7]   Regional imager for low-resolution functional imaging of the brain with diffusing near-infrared light [J].
Danen, RM ;
Wang, Y ;
Li, XD ;
Thayer, WS ;
Yodh, AG .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1998, 67 (01) :33-40
[8]   Assessment of the size, position, and optical properties of breast tumors in vivo by noninvasive optical methods [J].
Fantini, S ;
Walker, SA ;
Franceschini, MA ;
Kaschke, M ;
Schlag, PM ;
Moesta, KT .
APPLIED OPTICS, 1998, 37 (10) :1982-1989
[9]   AN IMPROVED DESIGN FOR A STABLE AND REPRODUCIBLE PHANTOM MATERIAL FOR USE IN NEAR-INFRARED SPECTROSCOPY AND IMAGING [J].
FIRBANK, M ;
ODA, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :955-961
[10]   Frequency-domain photon migration measurements of normal and malignant tissue optical properties in a human subject [J].
Fishkin, JB ;
Coquoz, O ;
Anderson, ER ;
Brenner, M ;
Tromberg, BJ .
APPLIED OPTICS, 1997, 36 (01) :10-20