Thermal Environment Assessment Reliability Using Temperature -Humidity Indices

被引:103
作者
Alfano, Francesca Romana d'Ambrosio [1 ]
Palella, Boris Igor [2 ]
Riccio, Giuseppe [2 ]
机构
[1] Univ Salerno, Dipartimento Ingn Meccan, I-84084 Salerno, Italy
[2] Univ Naples Federico II, Dipartimento Energet Termofluidodinam Applicata &, I-80125 Naples, Italy
关键词
Thermal environment assessment; Comfort indices; Stress indices;
D O I
10.2486/indhealth.MS1097
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A reliable assessment of the thermal environment should take into account the whole of the six parameters affecting the thermal sensation (air temperature, air velocity, humidity, mean radiant temperature, metabolic rate and thermo-physical properties of clothing). Anyway, the need of a quick evaluation based on few measurements and calculations has leaded to like best temperature-humidity indices instead of rational methods based on the heat balance on the human body. Among these, Canadian Humidex, preliminarily used only for weather forecasts, is becoming more and more widespread for a generalized assessment of both outdoor and indoor thermal environments. This custom arouses great controversies since using an index validated in outdoor conditions does not assure its indoor reliability. Moreover is it really possible to carry out the thermal environment assessment ignoring some of variables involved in the physiological response of the human body? Aiming to give a clear answer to these questions, this paper deals with a comparison between the assessment carried out according to the rational methods suggested by International Standards in force and the Humidex index. This combined analysis under hot stress situations (indoor and outdoor) has been preliminarily carried out; in a second phase the study deals with the indoor comfort prediction. Obtained results show that Humidex index very often leads to the underestimation of the workplace dangerousness and a poor reliability of comfort prediction when it is used in indoor situations.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 52 条
[1]   The role of measurement accuracy on the heat stress assessment according to ISO 7933: 2004 [J].
Alfano, F. R. d'Ambrosio ;
Palella, B. I. ;
Riccio, G. .
ENVIRONMENTAL HEALTH RISK IV, 2007, 11 :115-+
[2]  
ALFANO FRD, 2005, P 11 INT C ENV ERG Y, P503
[3]  
*AM C GOV IND HYG, 1999, THRESH LIM VAL CHEM
[4]  
Anderson SR, 1965, HUMIDEX CALCULATION
[5]  
[Anonymous], 1989, 7933 ISO
[6]  
[Anonymous], 1994, P CONT CLIM C BRNO
[7]  
[Anonymous], 47391 RNP MED RES CO
[8]  
[Anonymous], 1994, 7730 ISO
[9]  
[Anonymous], P 11 INT C ENV ERG Y
[10]  
[Anonymous], 2004, ERGONOMICS THERMAL E