Control and protection of a microgrid connected to utility through back-to-back converters

被引:47
作者
Majumder, Ritwik
Dewadasa, Manjula [1 ]
Ghosh, Arindam [1 ]
Ledwich, Gerard [1 ]
Zare, Firuz [1 ]
机构
[1] Queensland Univ Technol, Brisbane, Qld 4001, Australia
关键词
Autonomous microgrid; Back-to-back converter; Active and reactive power sharing; Protection; INVERTERS;
D O I
10.1016/j.epsr.2011.02.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses the control and protection of a microgrid that is connected to utility through back-to-back converters. The back-to-back converter connection facilitates bidirectional power flow between the utility and the microgrid. These converters can operate in two different modes-one in which a fixed amount of power is drawn from the utility and the other in which the microgrid power shortfall is supplied by the utility. In the case of a fault in the utility or microgrid side, the protection system should act not only to clear the fault but also to block the back-to-back converters such that its dc bus voltage does not fall during fault. Furthermore, a converter internal mechanism prevents it from supplying high current during a fault and this complicates the operation of a protection system. To overcome this, an admittance based relay scheme is proposed, which has an inverse time characteristic based on measured admittance of the line. The proposed protection and control schemes are able to ensure reliable operation of the microgrid. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1424 / 1435
页数:12
相关论文
共 16 条
[1]  
[Anonymous], IEEE AS PAC REG 10 C
[2]  
[Anonymous], KLUWERS POWER ELECT
[3]   CONTROL OF PARALLEL CONNECTED INVERTERS IN STANDALONE AC SUPPLY-SYSTEMS [J].
CHANDORKAR, MC ;
DIVAN, DM ;
ADAPA, R .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (01) :136-143
[4]  
*CONS EL REL TECHN, WHIT PAP INT DISTR E
[5]   Performance study of two different compensating devices in a custom power park [J].
Ghosh, A .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (04) :521-528
[6]   A new approach to load balancing and power factor correction in power distribution system [J].
Ghosh, A ;
Joshi, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) :417-422
[7]  
Lasseter RH, 2002, 2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P305, DOI 10.1109/PESW.2002.985003
[8]   Load sharing and power quality enhanced operation of a distributed microgrid [J].
Majumder, R. ;
Ghosh, A. ;
Ledwich, G. ;
Zare, F. .
IET RENEWABLE POWER GENERATION, 2009, 3 (02) :109-119
[9]   Application of out-of-step relaying for small generators in distributed generation [J].
Malmedal, K ;
Sen, PK ;
Nelson, JP .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (06) :1506-1514
[10]   Modeling, analysis and testing of autonomous operation of an inverter-based microgrid [J].
Pogaku, Nagaraju ;
Prodanovic, Milan ;
Green, Timothy C. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) :613-625