Blind separation of multichannel electrogastrograms using independent component analysis based on a neural network

被引:36
作者
Wang, ZS
Cheung, JY
Chen, JDZ
机构
[1] Lynn Inst Healthcare Res, Oklahoma City, OK 73112 USA
[2] Univ Oklahoma, Dept Elect & Comp Engn, Oklahoma City, OK USA
关键词
electrogastrogram; blind source separation; independent component analysis; neural network;
D O I
10.1007/BF02513270
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The electrogastrogram (EGG) is an abdominal surface measurement of gastric myo-electrical activity which regulates gastric contractions. It is of great clinical importance to record and analyse multichannel EGGs, which provide more information on the propagation and co-ordination of gastric contractions. EGGs are, however, contaminated by myo-electric interference from other organs and artefacts such as motion and respiration. The aim of the study is to separate the gastric signal from noisy multichannel EGGs without any information on the interference, using independent component analysis. A neural-network model is proposed, and corresponding unsupervised learning algorithms are developed to achieve the separation. The performance of the proposed method is investigated using artificial data simulating real EGG signals. Experimental EGG data are obtained from humans and dogs. The processed results of both simulated and real EGG data show the following: first, the proposed method is able to separate normal gastric slow waves from respiratory artefacts and random noises. It is also able to extract gastric slow waves, even when the EGG is contaminated by severe respiratory and ECG artefacts. Secondly, when the stomach contains various gastric electric signals with different frequencies, the proposed method is able to separate these different signals, as illustrated by simulations. These data suggest that the proposed method can be used to separate gastric slow waves, respiratory and motion artefacts, and intestinal myo-electric interference that are mixed in the EGG. It can also be used to detect gastric slow-wave uncoupling, during which the stomach has multiple gastric signals with different frequencies. It is believed that the proposed method may also be applicable to other biomedical signals.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 20 条
[1]   ELECTROGASTROGRAPHY - CURRENT ASSESSMENT AND FUTURE PERSPECTIVES [J].
ABELL, TL ;
MALAGELADA, JR .
DIGESTIVE DISEASES AND SCIENCES, 1988, 33 (08) :982-992
[2]  
Alvarez WC, 1922, J AMER MED ASSOC, V78, P1116
[3]   BLIND SEPARATION OF SOURCES - A NONLINEAR NEURAL ALGORITHM [J].
BUREL, G .
NEURAL NETWORKS, 1992, 5 (06) :937-947
[4]  
Chen J.Z., 1994, ELECTROGASTROGRAPHY
[5]  
CHEN JD, 1993, AM J GASTROENTEROL, V88, P1324
[6]   ADAPTIVE METHOD FOR CANCELLATION OF RESPIRATORY ARTIFACT IN ELECTROGASTRIC MEASUREMENTS [J].
CHEN, JD ;
VANDEWALLE, J ;
SANSEN, W ;
VANTRAPPEN, G ;
JANSSENS, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (01) :57-63
[7]   Abnormal gastric myoelectrical activity and delayed gastric emptying in patients with symptoms suggestive of gastroparesis [J].
Chen, JDZ ;
Lin, ZY ;
Pan, J ;
McCallum, RW .
DIGESTIVE DISEASES AND SCIENCES, 1996, 41 (08) :1538-1545
[8]   INDEPENDENT COMPONENT ANALYSIS, A NEW CONCEPT [J].
COMON, P .
SIGNAL PROCESSING, 1994, 36 (03) :287-314
[9]   NONINVASIVE ASSESSMENT OF HUMAN GASTRIC MOTOR FUNCTION [J].
FAMILONI, BO ;
KINGMA, YJ ;
BOWES, KL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (01) :30-36
[10]  
HYVARINEN A, 1996, P INT C NEUR NETW BO, V7, P17