Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip

被引:56
作者
Zhang, Yuan Z. [1 ]
Chen, Bin [2 ]
Lu, Sheng [3 ]
Yang, Yong [1 ]
Zhao, Jian M. [1 ]
Liu, Rui [1 ]
Li, Yan B. [4 ]
Pei, Guo X. [5 ]
机构
[1] Inner Mongolia Med Coll, Affiliated Hosp, Dept Orthopaed, Hohhot, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hosp 1, Dept Orthopaed, Hangzhou 310003, Zhejiang, Peoples R China
[3] Kunming Gen Hosp, Dept Orthoped, Kunming, Peoples R China
[4] NanHua Univ, Dept Anat, Henyang, Peoples R China
[5] Fourth Mil Med Univ, Xijing Hosp, Dept Orthopaed, Xian 710032, Peoples R China
关键词
computer-assisted surgery planning; development dysplasia of the hip; total hip arthroplasty; navigation template; PEDICLE SCREW PLACEMENT; INDIVIDUAL TEMPLATES; SURFACE REPLACEMENT; ORTHOPEDIC-SURGERY; OSTEOARTHRITIS; ORIENTATION; DISLOCATION; SUBLUXATION; GUIDANCE; METAL;
D O I
10.1002/rcs.423
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. Methods From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Results Based on the predetermined abduction angle 45 degrees and anteversion angle 18 degrees, after 1 year follow-up, the NT group showed significantly smaller differences (1.6 degrees +/- 0.4 degrees, 1.9 degrees +/- 1.1 degrees) from the predetermined angles than those in the control group (5.8 degrees +/- 2.9 degrees, 3.9 degrees +/- 2.5 degrees) (P < 0.05). Conclusions The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate location of prosthesis with a low cost-performance ratio without excessive technical workload on the surgical team. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 34 条
[1]
Acetabular dysplasia after treatment for developmental dysplasia of the hip - Implications for secondary procedures [J].
Albinana, J ;
Dolan, LA ;
Spratt, KF ;
Morcuende, J ;
Meyer, MD ;
Weinstein, SL .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :876-886
[2]
Amstutz H C, 1998, J Orthop Sci, V3, P169, DOI 10.1007/s007760050038
[3]
TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[4]
Personalised image-based templates for intra-operative guidance [J].
Berry, E ;
Cuppone, M ;
Porada, S ;
Millner, PA ;
Rao, A ;
Chiverton, N ;
Seedhom, BB .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H2) :111-118
[5]
Computer-assisted orthopedic surgery with individual templates and comparison to conventional operation method [J].
Birnbaum, K ;
Schkommodau, E ;
Decker, N ;
Prescher, A ;
Klapper, U ;
Radermacher, K .
SPINE, 2001, 26 (04) :365-369
[6]
Determination of the rotational center of the hip [J].
Boudriot, Ulrich ;
Hilgert, J. ;
Hinrichs, F. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (06) :417-420
[7]
LOW-FRICTION ARTHROPLASTY IN CONGENITAL SUBLUXATION OF HIP [J].
CHARNLEY, J ;
FEAGIN, JA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (91) :98-113
[8]
Crawford JR, 2005, HIP INT, V15, P195, DOI 10.5301/HIP.2008.5286
[9]
TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CROWE, JF ;
MANI, VJ ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) :15-23
[10]
Total hip arthroplasty in patients younger than 30 years of age following developmental dysplasia of hip (DDH) in infancy [J].
Dudkiewicz, I ;
Salai, M ;
Ganel, A ;
Blankstein, A ;
Chechik, A .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (03) :139-142