Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization

被引:113
作者
Fiers, Tom [1 ]
Casetta, Bruno [2 ]
Bernaert, Brigitte [1 ]
Vandersypt, Eric [1 ]
Debock, Martine [1 ]
Kaufman, Jean-Marc [1 ]
机构
[1] Ghent Univ Hosp, Dept Hormonol, B-9000 Ghent, Belgium
[2] AB Sciex, Brugherio, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 893卷
关键词
Estrone; Estradiol; Estrogens; Tandem mass spectrometry; POSTMENOPAUSAL WOMEN; BREAST-CANCER; OLDER MEN; ESTROGENS; METABOLITES; RISK; FRACTURES; BIOASSAY; ASSAY;
D O I
10.1016/j.jchromb.2012.02.034
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Measurement of estrone (E1) and estradiol (E2) values < 1 pg/mL (3.7 pmol/L) is necessary for postmenopausal, pediatric and male serum samples. Until now this was rarely reached and only through derivatization which can present problems for estradiol. A very sensitive LC-MS/MS method was developed avoiding derivatization, convenient for large-scale studies. The desired sensitivity and specificity were achieved using ESI negative mode, LLE and a 2D chromatography consisting of a trapping column and a second dimension reverse-phase C8 analytical column. A mixture of an aqueous solution of ammonium fluoride at 0.2 mM and methanol was used on the analytical column to further increase the sensitivity. Serum LOQ was <0.5 pg/mL (1.9 pmol/L) for E2 and E1 and recoveries ranged from 95 to 105%. No carry-over was detectable. Inter assay CV's were 4.0% at 21 pg/mL (77 pmol/L) for E2. 7.6% at 25 pg/mL (93 pmol/L) for E1. Comparison with commercial direct estrogen assays (Roche Diagnostics E170 for E2, Bioline RIA for E1) exposed analytical unsuitability (due to a combined lack of sensitivity and specificity) for the assay of male, postmenopausal or pediatric samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 62
页数:6
相关论文
共 25 条
[1]
Analysis of estrogens in serum and plasma from postmenopausal women: Past present, and future [J].
Blair, Ian A. .
STEROIDS, 2010, 75 (4-5) :297-306
[2]
Effects of Aromatase Inhibition on Bone Mineral Density and Bone Turnover in Older Men with Low Testosterone Levels [J].
Burnett-Bowie, Sherri-Ann M. ;
McKay, Elizabeth A. ;
Lee, Hang ;
Leder, Benjamin Z. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2009, 94 (12) :4785-4792
[3]
Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: Effect of diabetes [J].
Caruso, Donatella ;
Scurati, Samuele ;
Maschi, Omar ;
De Angelis, Leonardo ;
Roglio, Ilaria ;
Giatti, Silvia ;
Garcia-Segura, Luis Miguel ;
Melcangi, Roberto C. .
NEUROCHEMISTRY INTERNATIONAL, 2008, 52 (4-5) :560-568
[4]
Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry [J].
Ceglarek, Uta ;
Kortz, Linda ;
Leichtle, Alexander ;
Fiedler, Georg M. ;
Kratzsch, Juergen ;
Thiery, Joachim .
CLINICA CHIMICA ACTA, 2009, 401 (1-2) :114-118
[5]
Serum estradiol level and risk of breast cancer during treatment with raloxifene [J].
Cummings, SR ;
Duong, T ;
Kenyon, E ;
Cauley, JA ;
Whitehead, M ;
Krueger, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (02) :216-220
[6]
Derivatization procedures for the detection of estrogenic chemicals by gas chromatography/mass spectrometry [J].
Ding, WH ;
Chiang, CC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :56-63
[7]
Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization [J].
Guo, Tiedong ;
Gu, Jianghong ;
Soldin, Offie P. ;
Singh, Ravinder J. ;
Soldin, Steven J. .
CLINICAL BIOCHEMISTRY, 2008, 41 (09) :736-741
[8]
Development and validation of a sensitive liquid chromatography-tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatization [J].
Harwood, D. Tim ;
Handelsman, David J. .
CLINICA CHIMICA ACTA, 2009, 409 (1-2) :78-84
[9]
High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol [J].
Kushnir, Mark M. ;
Rockwood, Alan L. ;
Bergquist, Jonas ;
Varshavsky, Marina ;
Roberts, William L. ;
Yue, Bingfang ;
Bunker, Ashley M. ;
Meikle, A. Wayne .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (04) :530-539
[10]
Comparison of methods to measure low serum estradiol levels in postmenopausal women [J].
Lee, Jennifer S. ;
Ettinger, Bruce ;
Stanczyk, Frank Z. ;
Vittinghoff, Eric ;
Hanes, Vladimir ;
Cauley, Jane A. ;
Chandler, Walt ;
Settlage, Jim ;
Beattie, Mary S. ;
Folkerd, Elizabeth ;
Dowsett, Mitch ;
Grady, Deborah ;
Cummings, Steven R. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2006, 91 (10) :3791-3797