Diagnosing hypertension by intradialytic blood pressure recordings

被引:62
作者
Agarwal, Rajiv [1 ,2 ]
Metiku, Tesfamariam [1 ,2 ]
Tegegne, Getachew G. [1 ,2 ]
Light, Robert P. [1 ,2 ]
Bunaye, Zerihun [1 ,2 ]
Bekele, Dagim M. [1 ,2 ]
Kelley, Ken [3 ]
机构
[1] Indiana Univ, Sch Med, Dept Med, Div Nephrol, Indianapolis, IN USA
[2] Richard L Roudebush Vet Adm Med Ctr, Indianapolis, IN 46202 USA
[3] Indiana Univ, Inquiry Methodol Program, Bloomington, IN USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2008年 / 3卷 / 05期
关键词
D O I
10.2215/CJN.01510308
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: The diagnosis of hypertension among hemodialysis patients by predialysis or postdialysis blood pressure (BP) recordings is imprecise and biased and has poor test-retest reliability. The use of intradialytic BP measurements to diagnose hypertension is unknown. Design, setting, participants, & measurements: A diagnostic-test study was done with interdialytic ambulatory BP as reference standard. Index BP recordings tested were: predialysis (method 1), postdialysis (method 2), intradialytic (method 3), intradialytic including predialyis and postdialysis (method 4), and the average of predialysis and postdialysis (method 5). Each index BP was recorded over six consecutive dialysis treatments. Results: There were differences among index BP measurements in reproducibility, bias, precision, and accuracy. Method 4 was the most reproducible (intraclass correlation coefficient = 0.70 for systolic and diastolic BP). All 5 measurement methods overestimated 44-h ambulatory systolic BP. Methods 2, 3, or 4 overestimated ambulatory systolic BP by only a small amount. Method 4 was the most precise and accurate. For diagnosis of hypertension, BP cut-point by method 4 of 135/75 mmHg, had a sensitivity of 90.4% and specificity of 75.9% for systolic BP (area under ROC curve 0.90). Median cut-off systolic BP of 140 mmHg from a single dialysis provides approximately 80% sensitivity and 80% specificity in diagnosing systolic hypertension; a median cut-off diastolic BP of 80 mmHg provides approximately 75% sensitivity and 75% specificity in diagnosing diastolic hypertension. Conclusions: Consideration of intradialytic BP measurements together with predialysis and postdialysis BP measurements improves the reproducibility, bias, precision, and accuracy of BP measurement compared with predialysis or postdialysis measurements.
引用
收藏
页码:1364 / 1372
页数:9
相关论文
共 27 条
[1]   Hypertension and survival in chronic hemodialysis patients - Past lessons and future opportunities [J].
Agarwal, R .
KIDNEY INTERNATIONAL, 2005, 67 (01) :1-13
[2]   Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients [J].
Agarwal, R ;
Andersen, MJ ;
Bishu, K ;
Saha, C .
KIDNEY INTERNATIONAL, 2006, 69 (05) :900-906
[3]   Out-of-hemodialysis-unit blood pressure is a superior determinant of left ventricular hypertrophy [J].
Agarwal, R ;
Brim, NJ ;
Mahenthiran, J ;
Andersen, MJ ;
Saha, C .
HYPERTENSION, 2006, 47 (01) :62-68
[4]   Assessment of blood pressure in hemodialysis patients [J].
Agarwal, R .
SEMINARS IN DIALYSIS, 2002, 15 (05) :299-304
[5]   Supervised atenolol therapy in the management of hemodialysis hypertension [J].
Agarwal, R .
KIDNEY INTERNATIONAL, 1999, 55 (04) :1528-1535
[6]   Location not quantity of blood pressure measurements predicts mortality in hemodialysis patients [J].
Agarwal, Rajiv ;
Andersen, Martin J. ;
Light, Robert P. .
AMERICAN JOURNAL OF NEPHROLOGY, 2008, 28 (02) :210-217
[7]   Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure [J].
Agarwal, Rajiv ;
Peixoto, Aldo J. ;
Santos, Sergio F. F. ;
Zoccali, Carmine .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (03) :389-398
[8]  
Agarwal Rajiv, 2004, Hemodial Int, V8, P207, DOI 10.1111/j.1492-7535.2004.01097.x
[9]   Home blood pressures are of greater prognostic value than hemodialysis unit recordings [J].
Alborzi, Pooneh ;
Patel, Nina ;
Agarwal, Rajiv .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (06) :1228-1234
[10]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845