Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept

被引:165
作者
Chen, Yuxiang [1 ]
Athienitis, A. K. [1 ]
Galal, Khaled [1 ]
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Net-zero energy solar house; Building-integrated photovoltaic-thermal system; Passive solar heating; Active solar heating; Thermal modeling;
D O I
10.1016/j.solener.2010.06.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
This paper is the first of two papers that describe the modeling, design, and performance assessment based on monitored data of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) in a prefabricated, two-storey detached, low energy solar house. This house, with a design goal of near net-zero annual energy consumption, was constructed in 2007 in Eastman, Quebec, Canada - a cold climate area. Several novel solar technologies are integrated into the house and with passive solar design to reach this goal. An air-based open-loop BIPV/T system produces electricity and collects heat simultaneously. Building-integrated thermal mass is utilized both in passive and active forms. Distributed thermal mass in the direct gain area and relatively large south facing triple-glazed windows (about 9% of floor area) are employed to collect and store passive solar gains. An active thermal energy storage system (TES) stores part of the collected thermal energy from the BIPV/T system, thus reducing the energy consumption of the house ground source heat pump heating system. This paper focuses on the BIPV/T system and the integrated energy concept of the house. Monitored data indicate that the BIPV/T system has a typical efficiency of about 20% for thermal energy collection, and the annual space heating energy consumption of the house is about 5% of the national average. A thermal model of the BIPV/T system suitable for preliminary design and control of the airflow is developed and verified with monitored data. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1892 / 1907
页数:16
相关论文
共 36 条
[1]
Anderson B., 1990, Solar Building Architecture
[2]
[Anonymous], 2005, ASHRAE HDB
[3]
[Anonymous], 1980, Numerical Heat Transfer and Fluid Flow. Series in computational methods in mechanics and thermal sciences
[4]
Athienitis A.K., 2002, THERMAL ANAL DESIGN
[5]
Athienitis A.K., 1994, BUILDING THERMAL ANA
[6]
The effect of solar radiation on dynamic thermal performance of floor heating systems [J].
Athienitis, AK ;
Chen, Y .
SOLAR ENERGY, 2000, 69 (03) :229-237
[7]
Balcomb J.D., 1992, PASSIVE SOLAR BUILDI
[8]
Balcomb J.D., 1983, HEAT STORAGE DISTRIB
[9]
Photovoltaic cogeneration in the built environment [J].
Bazilian, MD ;
Leenders, F ;
Van der Ree, BGC ;
Prasad, D .
SOLAR ENERGY, 2001, 71 (01) :57-69
[10]
Building-integrated PV modules [J].
Benemann, J ;
Chehab, O ;
Schaar-Gabriel, E .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2001, 67 (1-4) :345-354