Specimen diameter and "side artifacts" in cancellous bone evaluated using end-constrained elastic tension

被引:28
作者
Lievers, W. B. [1 ,2 ]
Petryshyn, A. C. [1 ]
Poljsak, A. S. [1 ]
Waldman, S. D. [1 ,2 ,3 ]
Pilkey, A. K. [1 ,2 ]
机构
[1] Queens Univ, Dept Mech & Mat Engn, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Human Mobil Res Ctr, Kingston, ON K7L 3N6, Canada
[3] Queens Univ, Dept Chem Engn, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cancellolls bone; Specimen diameter; Elastic modulus; Continuum limit; DUCTILE CELLULAR SOLIDS; TRABECULAR BONE; MECHANICAL-BEHAVIOR; STRENGTH; MODULUS; DEPENDENCE; BIOMECHANICS;
D O I
10.1016/j.bone.2010.03.024
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
In cancellous bone testing of cored samples, side artifacts are the underestimation of the true (i.e. in situ) mechanical properties due to the severing of the trabecular network during specimen preparation. Although other researchers have suggested correction factors derived from finite element method (FEM) models, it is proposed that side effects can be minimized by increasing the specimen diameter. Six different diameter specimens (3.1-10.6 mm), from two different anatomic sites (bovine femoral condyle and bovine lumbar vertebrae), were mechanically tested in elastic tension using an epoxy endcap protocol to eliminate end artifacts. Elastic modulus was found to be significantly affected by diameter in both sites. For example, the 5.1 mm samples underestimated the elastic modulus of the 10.6 mm samples by an average of roughly 20%. Yet no statistical difference was detected between the 8.3 and 10.6 mm samples in either anatomic site, suggesting that 8.3 mm diameter specimens were sufficiently large to avoid side artifacts. FEM models created from micro-CT images reveal that modulus approaches an asymptotic value with increasing diameter, and demonstrate an architecture-dependent drop in modulus at decreasing diameters. These results confirm, both experimentally and numerically, that side effects can be ignored given a suitably large specimen diameter and that this minimum diameter will be dependent on the cancellous architecture. An important implication of the latter result is that specimen diameters must be chosen appropriately when comparing test groups with different architectures (e.g. normal versus osteoporotic) to ensure that the magnitude of side artifacts does not confound the true differences between the groups. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 32 条
[1]
Size effects in ductile cellular solids. Part II: experimental results [J].
Andrews, EW ;
Gioux, G ;
Onck, P ;
Gibson, LJ .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2001, 43 (03) :701-713
[2]
REVISED STANDARD VALUES FOR PH MEASUREMENTS FROM 0 TO 95 DEGREES C [J].
BATES, RG .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1962, 66 (02) :179-+
[3]
Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site [J].
BeVill, Grant ;
Easley, Sarah K. ;
Keaveny, Tony M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (15) :3381-3388
[4]
The influence of boundary conditions and loading mode on high-resolution finite element-computed trabecular tissue properties [J].
Bevill, Grant ;
Eswaran, Senthil K. ;
Farahmand, Farhad ;
Keaveny, Tony M. .
BONE, 2009, 44 (04) :573-578
[5]
Regional differences in mechanical and material properties of femoral head cancellous bone in health and osteoarthritis [J].
Brown, SJ ;
Pollintine, P ;
Powell, DE ;
Davie, MWJ ;
Sharp, CA .
CALCIFIED TISSUE INTERNATIONAL, 2002, 71 (03) :227-234
[6]
COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[7]
TENSILE FRACTURE OF CANCELLOUS BONE [J].
CARTER, DR ;
SCHWAB, GH ;
SPENGLER, DM .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (05) :733-741
[8]
Bounds on the effective anisotropic elastic constants [J].
Cowin, SC ;
Yang, G ;
Mehrabadi, MM .
JOURNAL OF ELASTICITY, 1999, 57 (01) :1-24
[9]
Cell size effect analysis of the effective Young's modulus of sandwich core [J].
Dai, Gaoming ;
Zhang, Weihong .
COMPUTATIONAL MATERIALS SCIENCE, 2009, 46 (03) :744-748
[10]
CHARACTERIZATION OF MICROSTRUCTURAL ANISOTROPY IN ORTHOTROPIC MATERIALS USING A 2ND RANK TENSOR [J].
HARRIGAN, TP ;
MANN, RW .
JOURNAL OF MATERIALS SCIENCE, 1984, 19 (03) :761-767