Serum free light chain (FLC) measurement can aid capillary zone electrophoresis in detecting subtle FLC-producing M proteins

被引:52
作者
Bakshi, NA
Gulbranson, R
Garstka, D
Bradwell, AR
Keren, DF
机构
[1] Warde Med Lab, Ann Arbor, MI 48108 USA
[2] Univ Michigan, Ann Arbor, MI 48108 USA
[3] Binding Site, Birmingham, W Midlands, England
[4] Univ Birmingham, Sch Med, Dept Immunol & Infect, Birmingham, W Midlands, England
关键词
serum free light chain; monoclonal gammopathy; M protein; multiple myeloma; chronic lymphocytic leukemia; lymphocytosis; serum protein electrophoresis; capillary zone electrophoresis; immunofixation;
D O I
10.1309/XE3UDARKW1B9EMWM
中图分类号
R36 [病理学];
学科分类号
100104 [病理学与病理生理学];
摘要
We hypothesized that using a free light chain (FLC) assay as an adjunct to capillary zone electrophoresis (CZE) could improve detection of lymphoplasmacytic processes. We prospectively studied 1, 003 consecutive serum samples submitted for routine protein electrophoresis and/or immunofixation electrophoresis by CZE and FLC. Samples from patients previously characterized as having M proteins were excluded. Protein electrophoresis was read by a pathologist unaware of the FLC results. Sixteen cases revealed an abnormal free kappa/lambda ratio in which CZE did not demonstrate an M protein. Nine cases of B-lymphocyte or plasma cell proliferative processes were detected by an abnormal free kappa/lambda ratio in which CZE did not demonstrate an M protein. Cases with low free kappa/lambda ratios included 1 chronic lymphocytic leukemia (CLL), 1 IgM lambda with aplastic anemia, and 1 lambda light chain myeloma. Cases with high free kappa/lambda ratios included 2 CLL, 1 lymphocytosis (possibly early CLL), I K light chain myeloma, 1 atypical lymphoma with neuropathy, and 1 nonsecretory myeloma. Addition of the free kappa/lambda ratio to CZE increases the yield of lymphocyte and plasma cell proliferative processes detected by 56%.
引用
收藏
页码:214 / 218
页数:5
相关论文
共 13 条
[1]
Quantitative analysis of serum free light chains - A new marker for the diagnostic evaluation of primary systemic amyloidosis [J].
Abraham, RS ;
Katzmann, JA ;
Clark, RJ ;
Bradwell, AR ;
Kyle, RA ;
Gertz, MA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (02) :274-278
[2]
Automated serum protein electrophoresis by Capillarys® [J].
Bossuyt, X ;
Lissoir, B ;
Mariën, G ;
Maisin, D ;
Vunckx, J ;
Blanckaert, N ;
Wallemacq, P .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (05) :704-710
[3]
Bossuyt X, 2001, CLIN CHEM, V47, P1477
[4]
Serum test for assessment of patients with Bence Jones myeloma [J].
Bradwell, AR ;
Carr-Smith, HD ;
Mead, GP ;
Harvey, TC ;
Drayson, MT .
LANCET, 2003, 361 (9356) :489-491
[5]
BRADWELL AR, 2001, CLIN CHEM, V47, P637
[6]
Katzmann JA, 2002, CLIN CHEM, V48, P1437
[7]
Katzmann JA, 1998, AM J CLIN PATHOL, V110, P503
[8]
Keren DF, 1999, ARCH PATHOL LAB MED, V123, P106
[9]
Outcome in systemic AL amyloidosis in relation to changes in concentration of circulating free immunoglobulin light chains following chemotherapy [J].
Lachmann, HJ ;
Gallimore, R ;
Gillmore, JD ;
Carr-Smith, HD ;
Bradwell, AR ;
Pepys, MB ;
Hawkins, PN .
BRITISH JOURNAL OF HAEMATOLOGY, 2003, 122 (01) :78-84
[10]
Mariën G, 2002, CLIN CHEM, V48, P1600