Laboratory performance of haemophilia centres in developing countries: 3 years' experience of the World Federation of Hemophilia External Quality Assessment Scheme

被引:12
作者
Jennings, I [1 ]
Kitchen, S [1 ]
Woods, TAL [1 ]
Preston, FE [1 ]
机构
[1] UK NEQAS Coagulat, Sheffield S10 2TJ, S Yorkshire, England
关键词
External Quality Assessment; factor IX : C; factor VIII : C; International Haemophilia Training Centres; von Willebrand factor;
D O I
10.1111/j.1365-2516.1998.00174.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A World Federation of Hemophilia External Quality Assessment Scheme has been established to promote high standards of laboratory performance in haemophilia centres worldwide. Results from 21 International Haemophilia Training Centres (IHTCs) provide target values for the prothrombin time (PT), activated partial thromboplastin time (APTT), factor VIII:C, IX:C and von Willebrand factor (VWF) assays, against which the performance of Haemophilia Centres in developing countries (HCs) can be assessed. Eight surveys were distributed over a 3-year period between 1994 and 1997. A higher proportion of HCs failed to identify an abnormal PT or APTT in samples from donors with mild deficiencies of the extrinsic and intrinsic systems, respectively. For factor VIII:C and IX:C assays, agreement between HC results was consistently poorer than between IHTCs. However, improvement in between-centre agreement could be seen for two samples distributed on more than one occasion. A minority of HCs perform assays for VWF, and a questionnaire revealed equipment and reagent costs as limiting the range of assays which could be carried out in several centres. However, agreement was in some cases better between those HCs that did perform VWF assays than between IHTCs. The problems of screening test sensitivity and between-centre agreement for factor assays need to be addressed, together with the limitations which prevent HCs from performing a full range of tests in the diagnosis and treatment of bleeding disorders.
引用
收藏
页码:739 / 746
页数:8
相关论文
共 6 条
  • [1] ARKIN CF, 1992, ARCH PATHOL LAB MED, V116, P908
  • [2] THROMBOPLASTIN - SENSITIVITY, PRECISION AND OTHER CHARACTERISTICS
    DENSON, KWE
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 1988, 10 (03): : 315 - 328
  • [3] Development of a world federation of hemophilia external quality assessment scheme: Results of a pilot study
    Jennings, I
    Kitchen, S
    Woods, TAL
    Preston, FE
    [J]. HAEMOPHILIA, 1996, 2 (01) : 41 - 46
  • [4] JENNINGS I, 1995, BRIT J HAEMATOL, V89, P50
  • [5] KASPER CK, 1995, THROMB HAEMOSTASIS, V74, P987
  • [6] KITCHEN S, 1994, THROMB HAEMOSTASIS, V72, P426