Evaluation of compliance with a computerized protocol: Weaning from mechanical ventilator support using pressure support

被引:20
作者
Randolph, AG
Clemmer, TP
East, TD
Kinder, AT
Orme, JF
Wallace, CJ
Morris, AH
机构
[1] Univ Utah, Latter Day St Hosp, Div Pulm Med, Salt Lake City, UT 84143 USA
[2] Univ Utah, Latter Day St Hosp, Div Crit Care Med, Salt Lake City, UT 84143 USA
关键词
computerized protocol; mechanical ventilation; weaning; pressure support;
D O I
10.1016/S0169-2607(98)00062-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Study objectives: To use a computerized consultation system to evaluate the feasibility of a mechanical ventilator weaning protocol which used the rapid shallow breathing index to guide adjustments in pressure support. A program to monitor user compliance and reasons for noncompliance was built into the computerized consultation system. Methods: A total of nine critically ill patients (ten weaning episodes) were enrolled in the protocol. The respiratory therapists performed routine computer charting in the electronic database. They accepted or declined the explicit instructions generated by the computerized protocol and displayed on the bedside terminal. The consultation program monitored whether accepted instructions were implemented by the user. Results: Patient's therapy was controlled by protocol for a total of 1075 h (mean 108 h, range 4 to 339 h) and 94.8% (1321/1394) of instructions were followed by the clinical staff. Of the 42 instructions clinical staff refused to follow, 23 (55%) were extubation instructions. There were 52 (3.7%) incorrect instructions generated with 24 software errors, 21 errors in underlying logic, and seven user misunderstanding errors. Conclusions: A high level of user compliance with this protocol was achieved. The methods described herein to monitor compliance and reasons for noncompliance within a protocol are reusable in the domain of mechanical ventilation and possibly in other domains. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:201 / 215
页数:15
相关论文
共 27 条
[1]   PARTIALLY AND TOTALLY UNLOADING RESPIRATORY MUSCLES BASED ON REAL-TIME MEASUREMENTS OF WORK OF BREATHING - A CLINICAL APPROACH [J].
BANNER, MJ ;
KIRBY, RR ;
GABRIELLI, A ;
BLANCH, PB ;
LAYON, AJ .
CHEST, 1994, 106 (06) :1835-1842
[2]   COMPARISON OF 3 METHODS OF GRADUAL WITHDRAWAL FROM VENTILATORY SUPPORT DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
RAUSS, A ;
BENITO, S ;
CONTI, G ;
MANCEBO, J ;
REKIK, N ;
GASPARETTO, A ;
LEMAIRE, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :896-903
[3]  
Burns S M, 1994, Am J Crit Care, V3, P342
[4]   RANGE OF ACCURACY OF 2 WAVELENGTH OXIMETRY [J].
CHAPMAN, KR ;
LIU, FLW ;
WATSON, RM ;
REBUCK, AS .
CHEST, 1986, 89 (04) :540-542
[5]   Adverse drug events in hospitalized patients - Excess length of stay, extra costs, and attributable mortality [J].
Classen, DC ;
Pestotnik, SL ;
Evans, RS ;
Lloyd, JF ;
Burke, JP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (04) :301-306
[6]   Breathing measurement reduces false-negative classification of tachypneic preextubation trial failures [J].
Dehaven, CB ;
Kirton, OC ;
Morgan, JP ;
Hart, AML ;
Shatz, DV ;
Civetta, JM .
CRITICAL CARE MEDICINE, 1996, 24 (06) :976-980
[7]   Evaluation of a knowledge-based system providing ventilatory management and decision for extubation [J].
Dojat, M ;
Harf, A ;
Touchard, D ;
Laforest, M ;
Lemaire, F ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (03) :997-1004
[8]  
EAST T, 1995, CRIT CARE MED, V23, P27
[9]  
EAST T, 1992, INT J CLIN MONIT COM, V8, P263
[10]  
EAST T, 1994, TXB CRITICAL CARE