Modified oscillating gradient pulses for direct sampling of the diffusion spectrum suitable for imaging sequences

被引:48
作者
Parsons, EC [1 ]
Does, MD
Gore, JC
机构
[1] Yale Univ, Dept Appl Phys, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT USA
[3] Yale Univ, Dept Psychol, New Haven, CT 06520 USA
关键词
MRI diffusion; motional spectroscopy; oscillating gradients;
D O I
10.1016/S0730-725X(03)00155-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A variation of the oscillating gradient spin echo method had been developed, which isolates temporal frequencies of the dephasing spectrum. This allows sampling of the diffusion spectrum, the Fourier transform of the velocity correlation function (VCF). It has been shown that restriction and flow alter this function in ways that can be mathematically characterized, yielding quantitative information on restriction geometry and flow parameters. It is demonstrated that in many systems of interest, dispersion of velocity will produce a peak in the VCF spectrum near omega = 0, while restricted diffusion will manifest itself in the spectrum at higher frequencies. The method, therefore, may be useful for decoupling their effects on the apparent diffusion coefficient (ADC), as well as in revealing the physics of both phenomena. This method has been implemented in model systems of packed beads, yielding data consistent with theoretical models of restricted diffusion spectra and data from one previous study [1]. The method may have significant application to biology and medicine, as well as the study of transport phenomena in porous media and complex flow. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 24 条
[1]  
Callaghan PT, 1999, CONCEPT MAGNETIC RES, V11, P181, DOI 10.1002/(SICI)1099-0534(1999)11:4<181::AID-CMR1>3.0.CO
[2]  
2-T
[3]   FREQUENCY-DOMAIN ANALYSIS OF SPIN MOTION USING MODULATED-GRADIENT NMR [J].
CALLAGHAN, PT ;
STEPISNIK, J .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 117 (01) :118-122
[4]  
CALLAGHAN PT, 1996, PRINCIPLES NUCL MAGN, P492
[5]   Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain [J].
Does, MD ;
Parsons, EC ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) :206-215
[6]  
GROSS B, 1969, MESSTECHNIK, V77, P171
[7]   The application of porous-media theory to the investigation of time-dependent diffusion in in vivo systems [J].
Helmer, KG ;
Dardzinski, BJ ;
Sotak, CH .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :297-306
[8]   MEASURING DIFFUSION IN INHOMOGENEOUS SYSTEMS IN IMAGING MODE USING ANTISYMMETRIC SENSITIZING GRADIENTS [J].
HONG, XL ;
DIXON, WT .
JOURNAL OF MAGNETIC RESONANCE, 1992, 99 (03) :561-570
[9]   A GENERAL-MODEL OF MICROCIRCULATORY BLOOD-FLOW EFFECTS IN GRADIENT SENSITIZED MRI [J].
KENNAN, RP ;
GAO, JH ;
ZHONG, JH ;
GORE, JC .
MEDICAL PHYSICS, 1994, 21 (04) :539-545
[10]   TIME-DEPENDENT DIFFUSION-COEFFICIENT OF FLUIDS IN POROUS-MEDIA AS A PROBE OF SURFACE-TO-VOLUME RATIO [J].
LATOUR, LL ;
MITRA, PP ;
KLEINBERG, RL ;
SOTAK, CH .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 101 (03) :342-346