Optimal combination of discriminators for differentiating ventricular from supraventricular tachycardia by dual-chamber defibrillators

被引:38
作者
Glikson, M [1 ]
Swerdlow, CD
Gurevitz, OT
Daoud, E
Shivkumar, K
Wilkoff, B
Shipman, T
Friedman, PA
机构
[1] Sheba Med Ctr, IL-52621 Ramat Gan, Israel
[2] Sheba Med Ctr, Tel Hashomer, Israel
[3] Tel Aviv Univ, IL-52621 Tel Hashomer, Israel
[4] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[5] Riverside Methodist Hosp, Columbus, OH USA
[6] Univ Calif Los Angeles, Cardiac Arrhythmia Ctr, Los Angeles, CA 90024 USA
[7] Cleveland Clin, Cleveland, OH 44106 USA
[8] St Jude Med, Sylmar, CA USA
[9] Mayo Clin, Rochester, MN USA
关键词
implantable cardioverter defibrillator; detection ventricular tachycardia; supraventricular tachycardia; detection algorithm; discrimination algorithm; detection enhancement; inappropriate shocks;
D O I
10.1046/j.1540-8167.2005.40643.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dual-chamber implantable cardioverter defibrillators (ICDs) use discriminators to differentiate between supraventricular tachycardias (SVTs) and ventricular tachycardias (VT), the accuracy of which may depend on the type and method used. ICDs can combine rate branching of tachyarrhythmias according to their A:V relationship with two SVT-VT discriminators in each rate branch, using ANY (either) or ALL (both) logic. Our goal was to determine the optimal discriminator combination. Methods: Stored electrogram data from 596 spontaneous tachyarrhythmias from 203 patients with Photon DR ICDs were analyzed. Arrhythmias are first classified by the relationship of atrial and ventricular rates (rate branches V < A, V = A, and V > A) followed by additional discriminators: morphology and/or sudden onset if V = A; morphology and/or interval stability if V < A. Data were analyzed for all combinations of ANY and ALL logic. Results: Sensitivity and specificity were calculated for all spontaneous episodes in each analysis. V = A branch: ALL logic produced unacceptably low sensitivity, whereas morphology provided only similar sensitivity but better specificity than ANY logic. A > V branch: ANY logic provided adequate sensitivity. The combination of morphology only in V = A with interval stability or morphology (ANY logic) in V < A, provided the optimal result with sensitivity, specificity, positive, and negative predictive values of 99%, 79%, 87%, and 98%, respectively. Conclusion: SVT-VT combined discriminators strongly influence dual-chamber SVT-VT discrimination performance. In our study, optimal programming is morphology only in the V = A branch and morphology or interval stability (ANY) in the V < A branch. ALL logic should be used with caution due to loss of sensitivity.
引用
收藏
页码:732 / 739
页数:8
相关论文
共 26 条
[1]   Clinical investigation of a new dual-chamber implantable cardioverter defibrillator with improved rhythm discrimination capabilities [J].
Bailin, SJ ;
Niebauer, M ;
Tomassoni, G ;
Leman, R .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (02) :144-149
[2]   Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators [J].
Barold, HS ;
Newby, KH ;
Tomassoni, G ;
Kearney, M ;
Brandon, J ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07) :1347-1355
[3]   Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias [J].
Boriani, G ;
Wollmann, C ;
Biffi, M ;
Kühl, M ;
Schuchert, A ;
Sperzel, J ;
Stiller, S ;
Gasparini, G ;
Böcker, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :461-465
[4]   Rhythm discrimination by rate branch and QRS morphology in dual chamber implantable cardioverter defibrillators [J].
Boriani, G ;
Biffi, M ;
Dall'Acqua, A ;
Martignani, C ;
Frabetti, L ;
Zannoli, R ;
Branzi, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :466-470
[5]  
Brugada J, 1999, AM J CARDIOL, V83, p40D
[6]   Enhanced detection criteria in implantable defibrillators [J].
Brugada, J ;
Mont, L ;
Figueiredo, M ;
Valentino, M ;
Matas, M ;
Navarro-López, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (03) :261-268
[7]  
DEERING TF, 2003, PACING CLIN ELECTRO, V26, P1124
[8]   Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study [J].
Deisenhofer, I ;
Kolb, C ;
Ndrepepa, G ;
Schreieck, J ;
Karch, M ;
Schmieder, S ;
Zrenner, B ;
Schmitt, C .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (02) :134-142
[9]   Advanced rhythm discrimination for implantable cardioverter defibrillators using electrogram vector timing and correlation [J].
Gold, MR ;
Shorofsky, SR ;
Thompson, JA ;
Kim, J ;
Schwartz, M ;
Bocek, J ;
Lovett, EG ;
Hsu, W ;
Morris, MM ;
Lang, DJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (11) :1092-1097
[10]   ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673