In vitro and in vivo biocompatibility and corrosion behaviour of a bioabsorbable magnesium alloy coated with octacalcium phosphate and hydroxyapatite

被引:166
作者
Hiromoto, Sachiko [1 ]
Inoue, Motoki [1 ]
Taguchi, Tetsushi [1 ]
Yamane, Misao [2 ]
Ohtsu, Naofumi [2 ]
机构
[1] Natl Inst Mat Sci, Int Ctr Mat Nanoarchitecton WPI MANA, Biomat Unit, Tsukuba, Ibaraki 3050044, Japan
[2] Kitami Inst Technol, Instrumental Anal Ctr, Kitami, Hokkaido 0908507, Japan
关键词
Magnesium; Calcium phosphate coatings; Biocompatibility; Corrosion; In vivo; SPECTROPHOTOMETRIC DETERMINATION; CALCIUM-PHOSPHATE; STAINLESS-STEEL; PURE MAGNESIUM; COATINGS; BIODEGRADATION; PRECIPITATION; MULTICENTER; IMPLANTS; APATITE;
D O I
10.1016/j.actbio.2014.09.026
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Octacalcium phosphate (OCP) and hydroxyapatite (HAp) coatings were formed on Mg-3 mass% Al-1 mass% Zn (AZ31) magnesium alloy by a single-step chemical solution deposition method. Chemically polished AZ31 (Cpol-AZ31) and HAp- and OCP-coated AZ31 (HAp- and OCP-AZ31) were immersed in a medium for 52 weeks or implanted in transgenic mice for 16 weeks to examine the long-term corrosion behaviour and in situ inflammation behaviour. In the medium, Mg-ion release was restricted for the initial several days and the corrosion rate thereafter was suppressed by approximately one-half with the HAp and OCP coatings. HAp-AZ31 showed a similar to 20% lower corrosion rate than OCP-AZ31. Tissues of the transgenic mouse emit fluorescence in proportion to the degree of inflammation in situ. The luminescence intensity level was too low to be a problem regardless of the coatings. A thinner fibrous tissue layer was formed around OCP- and HAp-AZ31 than around Cpol-AZ31, indicating that the HAP and OCP coatings suppressed corrosion and foreign-body reaction in vivo. Visible pits were formed in filiform and round shapes in vitro and in vivo, respectively. Corrosion was observed underneath the coatings, and almost uniform corrosion took place in vitro, while local corrosion was predominant in vivo. These differences in corrosion morphology are attributed to the adhesion of tissues and the lower diffusivity on the surface in vivo than that in vitro. Dissolution behaviour of OCP crystals in vivo was different from that in vitro. It was demonstrated that the HAp and OCP coatings developed have great potential for a biocompatible and corrosion protection coating. (C) 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:520 / 530
页数:11
相关论文
共 52 条
[1]
Al-Abdullat Y, 2001, MAT T, V42, P4
[2]
Anderson JM., 2004, Biomaterials Science, V2, P296
[3]
[Anonymous], 2000, JIS23712000
[4]
Aoki H, 1999, HYDROXYAPATITE
[5]
Increased phagocytosis and production of reactive oxygen species by neutrophils during magnesium deficiency in rats and inhibition by high magnesium concentration [J].
Bussière, FI ;
Gueux, E ;
Rock, E ;
Girardeau, JP ;
Tridon, A ;
Mazur, A ;
Rayssiguier, Y .
BRITISH JOURNAL OF NUTRITION, 2002, 87 (02) :107-113
[6]
In vitro and in vivo evaluations on osteogenesis and biodegradability of a ß-tricalcium phosphate coated magnesium alloy [J].
Chai, Hongwei ;
Guo, Lei ;
Wang, Xiantao ;
Gao, Xiaoyu ;
Liu, Kui ;
Fu, Yuping ;
Guan, Junlin ;
Tan, Lili ;
Yang, Ke .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (02) :293-304
[7]
Eichler Dominic, 2009, The Collectors: Calendar, P13
[8]
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial [J].
Erbel, Raimund ;
Di Mario, Carlo ;
Bartunek, Jozef ;
Bonnier, Johann ;
de Bruyne, Bernard ;
Eberli, Franz R. ;
Erne, Paul ;
Haude, Michael ;
Heublein, Bernd ;
Horrigan, Mark ;
Ilsley, Charles ;
Boese, Dirk ;
Koolen, Jacques ;
Luescher, Thomas F. ;
Weissman, Neil ;
Waksman, Ron .
LANCET, 2007, 369 (9576) :1869-1875
[9]
Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial [J].
Haude, Michael ;
Erbel, Raimund ;
Erne, Paul ;
Verheye, Stefan ;
Degen, Hubertus ;
Boese, Dirk ;
Vermeersch, Paul ;
Wijnbergen, Inge ;
Weissman, Neil ;
Prati, Francesco ;
Waksman, Ron ;
Koolen, Jacques .
LANCET, 2013, 381 (9869) :836-844
[10]
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? [J].
Heublein, B ;
Rohde, R ;
Kaese, V ;
Niemeyer, M ;
Hartung, W ;
Haverich, A .
HEART, 2003, 89 (06) :651-656