Computational hemodynamics of an implanted coronary Stent based on three-dimensional Cine angiography reconstruction

被引:11
作者
Chen, MCY
Lu, PC [1 ]
Chen, JSY
Hwang, NHC
机构
[1] Tamkang Univ, Dept Water Resources & Environm Engn, Taipei, Taiwan
[2] Natl Hlth Res Inst, Med Engn Div, Taipei, Taiwan
[3] Univ Colorado, Hlth Sci Ctr, Dept Med Cardiol, Denver, CO USA
关键词
D O I
10.1097/01.mat.0000169117.07070.fb
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 40 条
[1]
BARGERON CB, 1988, CARDIOVASC RES, V5, P340
[2]
Flows in stenotic vessels [J].
Berger, SA ;
Jou, LD .
ANNUAL REVIEW OF FLUID MECHANICS, 2000, 32 :347-382
[3]
Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[4]
Blood flow patterns in an anatomically realistic coronary vessel: Influence of three different reconstruction methods [J].
Berthier, B ;
Bouzerar, R ;
Legallais, C .
JOURNAL OF BIOMECHANICS, 2002, 35 (10) :1347-1356
[5]
ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS [J].
CARO, CG ;
FITZGERA.JM ;
SCHROTER, RC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046) :109-+
[6]
3-D reconstruction of coronary arterial tree to optimize angiographic visualization [J].
Chen, SJ ;
Carroll, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) :318-336
[7]
Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees [J].
Chen, SYJ ;
Metz, CE .
MEDICAL PHYSICS, 1997, 24 (05) :633-654
[8]
A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]
ACCURACY OF MR PHASE-CONTRAST VELOCITY-MEASUREMENTS FOR UNSTEADY-FLOW [J].
FRAYNE, R ;
STEINMAN, DA ;
ETHIER, CR ;
RUTT, BK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :428-431
[10]
ARTERIAL GEOMETRY AFFECTS HEMODYNAMICS - A POTENTIAL RISK FACTOR FOR ATHEROSCLEROSIS [J].
FRIEDMAN, MH ;
DETERS, OJ ;
MARK, FF ;
BARGERON, CB ;
HUTCHINS, GM .