On line microdialysis sample cleanup for electrospray ionization mass-spectrometry of nucleic acid samples

被引:120
作者
Liu, CL [1 ]
Wu, QY [1 ]
Harms, AC [1 ]
Smith, RD [1 ]
机构
[1] PACIFIC NW NATL LAB, ENVIRONM MOL SCI LAB, RICHLAND, WA 99352 USA
关键词
D O I
10.1021/ac960286j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A major limitation of electrospray ionization mass spectrometry (ESI-MS) for oligonucleotide analysis arises due to sodium adduction, a problem that increases with molecular weight. Sodium adduction can preclude useful measurements when-limited sample sizes prevent off-line cleanup. A novel and generally useful on-line microdialysis technique is described for the rapid (similar to 1-5 min) DNA sample cleanup for ESI-MS. Mass spectra of oligonucleotides of different size and sequence showing no significant sodium adduct peaks were obtained using the on-line microdialysis system with sodium chloride concentrations as high as 250 mM. Signal-to-noise ratios were also greatly enhanced compared to direct infusion of the original samples. By using ammonium acetate ga the dialysis buffer, it was also found that the noncovalent association of double-stranded oligonucleotides could be preserved during the microdialysis process, allowing analysis by ESI-MS.
引用
收藏
页码:3295 / 3299
页数:5
相关论文
共 36 条
[1]   TRAPPING, DETECTION, AND MASS DETERMINATION OF COLIPHAGE T4 DNA IONS OF 10(8) DA BY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, RD ;
CHENG, XH ;
MITCHELL, DW ;
HOFSTADLER, SA ;
WU, QY ;
ROCKWOOD, AL ;
SHERMAN, MG ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (07) :1159-1163
[2]  
CHEN X, IN PRESS ANAL BIOCH
[3]   CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION [J].
CHENG, XH ;
GALE, DC ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :586-593
[4]   Molecular weight determination of plasmid DNA using electrospray ionization mass spectrometry [J].
Cheng, XH ;
Camp, DG ;
Wu, QY ;
Bakhtiar, R ;
Springer, DL ;
Morris, BJ ;
Bruce, JE ;
Anderson, GA ;
Edmonds, CG ;
Smith, RD .
NUCLEIC ACIDS RESEARCH, 1996, 24 (11) :2183-2189
[5]  
Covey T R, 1988, Rapid Commun Mass Spectrom, V2, P249, DOI 10.1002/rcm.1290021111
[6]   ONLINE COUPLING OF INVIVO MICRODIALYSIS WITH TANDEM MASS-SPECTROMETRY [J].
DETERDING, LJ ;
DIX, K ;
BURKA, LT ;
TOMER, KB .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2636-2641
[7]   TRIS(2-CHLOROETHYL) PHOSPHATE PHARMACOKINETICS IN THE FISCHER-344 RAT - A COMPARISON OF CONVENTIONAL METHODS AND IN-VIVO MICRODIALYSIS COUPLED WITH TANDEM MASS-SPECTROMETRY [J].
DIX, K ;
DETERDING, LJ ;
BURKA, LT ;
TOMER, KB .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (11) :1622-1629
[8]   ANALYSIS OF POLYMERASE CHAIN REACTION-AMPLIFIED DNA PRODUCTS BY MASS-SPECTROMETRY USING MATRIX-ASSISTED LASER-DESORPTION AND ELECTROSPRAY - CURRENT STATUS [J].
DOKTYCZ, MJ ;
HURST, GB ;
HABIBIGOUDARZI, S ;
MCLUCKEY, SA ;
TANG, K ;
CHEN, CH ;
UZIEL, M ;
JACOBSON, KB ;
WOYCHIK, RP ;
BUCHANAN, MV .
ANALYTICAL BIOCHEMISTRY, 1995, 230 (02) :205-214
[9]   ACCUMULATION AND STORAGE OF IONIZED DUPLEX DNA-MOLECULES IN A QUADRUPOLE ION-TRAP [J].
DOKTYCZ, MJ ;
HABIBIGOUDARZI, S ;
MCLUCKEY, SA .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3416-3422
[10]   Specific molecular mass detection of endogenously released neuropeptides using in vivo microdialysis mass spectrometry [J].
Emmett, MR ;
Andren, PE ;
Caprioli, RM .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 62 (1-2) :141-147