O2/CO2 coal combustion characteristics in a 50 kWth circulating fluidized bed
被引:90
作者:
论文数: 引用数:
h-index:
机构:
Duan, Lunbo
[1
]
Zhao, Changsui
论文数: 0引用数: 0
h-index: 0
机构:
Southeast Univ, Thermoenergy Engn Res Inst, Nanjing 210096, Peoples R ChinaSoutheast Univ, Thermoenergy Engn Res Inst, Nanjing 210096, Peoples R China
Zhao, Changsui
[1
]
论文数: 引用数:
h-index:
机构:
Zhou, Wu
[1
]
Qu, Chengrui
论文数: 0引用数: 0
h-index: 0
机构:
Southeast Univ, Thermoenergy Engn Res Inst, Nanjing 210096, Peoples R ChinaSoutheast Univ, Thermoenergy Engn Res Inst, Nanjing 210096, Peoples R China
Qu, Chengrui
[1
]
论文数: 引用数:
h-index:
机构:
Chen, Xiaoping
[1
]
机构:
[1] Southeast Univ, Thermoenergy Engn Res Inst, Nanjing 210096, Peoples R China
Combustion experiments of two Chinese coals were conducted in a 50 kW(th) circulating fluidized bed (CFB) combustor in air and O-2/CO2 atmospheres, and the effects of atmosphere and O-2 staging on combustion characteristics including temperature distribution profiles, combustion efficiency, gaseous pollutant emission and desulfurization efficiency were investigated. Results show that O-2 enrichment in the atmosphere elevates the temperature level in the riser and improves the combustion efficiency. Without limestone addition, O-2 enrichment in the atmosphere augments SO2 and NO emission and reduces CO emission. The desulfurization efficiency under higher O-2 concentration is higher with the same Ca/S molar ratio in O-2/CO2 atmosphere. O-2 staging provides more operation flexibility for oxy-fuel CFB combustion. As O-2 concentration in the primary gas increases, combustion efficiency and desulfurization efficiency are improved. O-2 staging can reduce the NO emission to a large extent in O-2/CO2 atmosphere. (C) 2011 Elsevier Ltd. All rights reserved.
机构:
Nagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, JapanNagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
Hu, YQ
;
论文数: 引用数:
h-index:
机构:
Kobayashi, N
;
Hasatani, M
论文数: 0引用数: 0
h-index: 0
机构:
Nagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, JapanNagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
机构:
Nagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, JapanNagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
Hu, YQ
;
论文数: 引用数:
h-index:
机构:
Kobayashi, N
;
Hasatani, M
论文数: 0引用数: 0
h-index: 0
机构:
Nagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, JapanNagoya Univ, Dept Energy Engn & Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan