Magnetization and diffusion effects in NMR imaging of hyperpolarized substances

被引:32
作者
Gao, JH
Lemen, L
Xiong, JH
Patyal, B
Fox, PT
机构
[1] Research Imaging Center, Texas Univ. Health Science Center, 7703 Floyd Curl Drive, San Antonio
关键词
gas; blood flow; diffusion; magnetization; SENSORY STIMULATION; RESONANCE; SIGNAL; FEASIBILITY; RESOLUTION; CONTRAST; XE-129; CORTEX; BLOOD; MRI;
D O I
10.1002/mrm.1910370123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The special magnetization characteristics of hyperpolarized noble gases have led to an interest in using these agents for new MRI applications. In this note, the magnetization effects and NMR signal dependence of two noble gases, He-3 and Xe-129, are modeled across a range of gradient-echo imaging parameters. Pulse-sequence analysis shows a wide variation in optimum flip angles between imaging of gas (e.g., He-3 or Xe-129) in air spaces (e.g., trachea and lung) and in blood vessels, To optimize imaging of the air spaces, it is also necessary to reduce the otherwise substantial signal losses from diffusion effects by increasing voxel size, The possibility of using hyperpolarized Xe-129 for functional MRI (fMRI) is discussed in view of the results from the blood flow analysis, The short-lived nature of the hyperpolarization opens up new possibilities, as well as new technical challenges, in its potential application as a blood-flow tracer.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 27 条
[1]  
ALBERT M, 1995, P SMR 3 ANN M NIC, P1201
[2]   MEASUREMENT OF XE-129 T1 IN BLOOD TO EXPLORE THE FEASIBILITY OF HYPERPOLARIZED XE-129 MRI [J].
ALBERT, MS ;
SCHEPKIN, VD ;
BUDINGER, TF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) :975-978
[3]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[4]  
ALBERT MS, 1992, P SMRM 11 ANN M, P2104
[5]  
ALBERT MS, 1992, P SMRM 11 ANN M, P4710
[6]  
[Anonymous], 1961, PRINCIPLES NUCLEAR M
[7]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[8]   PARTITION OF XENON AND IODOANTIPYRINE AMONG ERYTHROCYTES, PLASMA, AND MYOCARDIUM [J].
CARLIN, R ;
CHIEN, S .
CIRCULATION RESEARCH, 1977, 40 (05) :497-504
[9]   EFFECT OF HEMATOCRIT ON WASHOUT OF XENON AND IODOANTIPYRINE FROM DOG MYOCARDIUM [J].
CARLIN, R ;
CHIEN, S .
CIRCULATION RESEARCH, 1977, 40 (05) :505-509
[10]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824