Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR

被引:75
作者
de Vries, TJ
Fourkour, A
Punt, CJA
van de Locht, LTF
Wobbes, T
van den Bosch, S
de Rooij, MJM
Mensink, EJBM
Ruiter, DJ
van Muijen, GNP
机构
[1] Univ Nijmegen Hosp, Dept Pathol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen Hosp, Dept Med Oncol, NL-6500 HB Nijmegen, Netherlands
[3] Univ Nijmegen Hosp, Cent Hematol Lab, NL-6500 HB Nijmegen, Netherlands
[4] Univ Nijmegen Hosp, Dept Surg, NL-6500 HB Nijmegen, Netherlands
[5] Univ Nijmegen Hosp, Dept Med Stat, NL-6500 HB Nijmegen, Netherlands
[6] Univ Nijmegen Hosp, Dept Dermatol, NL-6500 HB Nijmegen, Netherlands
关键词
tyrosinase; MelanA/MART-1; circulating cancer cells; melanoma; quantitative RT-PCR;
D O I
10.1038/sj.bjc.6690436
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-I transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-I measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-I (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1-3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively MART-1 PCR had a better performance than tyrosinase PCR, Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1-4 times). When applying real-time quantitative PCR far tyrosinase and MART-I, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 33 条
  • [1] POLYMERASE CHAIN-REACTION DETECTION OF CIRCULATING MELANOCYTES AS A PROGNOSTIC MARKER IN PATIENTS WITH MELANOMA
    BATTAYANI, Z
    GROB, JJ
    XERRI, L
    NOE, C
    ZAROUR, H
    HOUVAENEGHEL, G
    DELPERO, JR
    BIRMBAUM, D
    HASSOUN, J
    BONERANDI, JJ
    [J]. ARCHIVES OF DERMATOLOGY, 1995, 131 (04) : 443 - 447
  • [2] Brandt B, 1996, CANCER RES, V56, P4556
  • [3] BROSSART P, 1995, CANCER RES, V55, P4065
  • [4] HEMATOGENOUS SPREAD OF MALIGNANT-MELANOMA CELLS IN DIFFERENT STAGES OF DISEASE
    BROSSART, P
    KEILHOLZ, U
    WILLHAUCK, M
    SCHEIBENBOGEN, C
    MOHLER, T
    HUNSTEIN, W
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1993, 101 (06) : 887 - 889
  • [5] DETECTION OF RESIDUAL TUMOR-CELLS IN PATIENTS WITH MALIGNANT-MELANOMA RESPONDING TO IMMUNOTHERAPY
    BROSSART, P
    KEILHOLZ, U
    SCHEIBENBOGEN, C
    MOHLER, T
    WILLHAUCK, M
    HUNSTEIN, W
    [J]. JOURNAL OF IMMUNOTHERAPY, 1994, 15 (01): : 38 - 41
  • [6] NEUROBLASTOMA CELL DETECTION BY REVERSE-TRANSCRIPTASE POLYMERASE CHAIN-REACTION (RT-PCR) FOR TYROSINE-HYDROXYLASE MESSENGER-RNA
    BURCHILL, SA
    BRADBURY, FM
    SMITH, B
    LEWIS, IJ
    SELBY, P
    [J]. INTERNATIONAL JOURNAL OF CANCER, 1994, 57 (05) : 671 - 675
  • [7] Polymerase chain reaction for detection of melanoma in peripheral blood: Too early to assess clinical value
    Buzaid, AC
    Balch, CM
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (09) : 569 - 570
  • [8] CHOMCZYNSKI P, 1987, ANAL BIOCHEM, V162, P156, DOI 10.1016/0003-2697(87)90021-2
  • [9] deVries TJ, 1997, CANCER RES, V57, P3223
  • [10] RT-PCR for tyrosinase-mRNA-positive cells in peripheral blood:: Evaluation strategy and correlation with known prognostic markers in 123 melanoma patients
    Farthmann, B
    Eberle, J
    Krasagakis, K
    Gstöttner, M
    Wang, NP
    Bisson, S
    Orfanos, CE
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1998, 110 (03) : 263 - 267