Stray radiation in the cardiac catheterisation laboratory

被引:33
作者
Balter, S [1 ]
机构
[1] Lenox Hill Hosp, New York, NY 10021 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a006468
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Staff radiation risk is related to the radiation field in which individuals work. Traditional protective measures focus on reducing stochastic risk. However, deterministic injury to the operator's hands cannot always be ignored. The stray radiation held is almost totally attributable to scatter from the patient. Its relative intensity is greatest near the entry port of the useful beam into the patient. The entry port moves during the procedure as the operator selects various required projections. Therefore, the relative exposure rate at any particular location in the laboratory changes with the clinical projection. The absolute scatter intensity is also dependent on the size and strength of the useful beam. Operators may put their hands near or in the useful beam. Leaded surgical gloves provide some overall finger protection for scatter fields. However, because of automatic dose rate controls, these gloves often increase risk when the operator's hands are seen on the image monitor.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 12 条
[1]
Exposure to cosmic radiation of British Airways flying crew on ultralonghaul routes [J].
Bagshaw, M ;
Irvine, D ;
Davies, DM .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1996, 53 (07) :495-498
[2]
Balter S., 1997, Medicamundi, V41, P36
[3]
Radiation exposure to the hands of operators during angiographic procedures [J].
Damilakis, J ;
Koukourakis, M ;
Hatjidakis, A ;
Karabekios, S ;
Gourtsoyiannis, N .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) :72-75
[4]
Primary beam exposure outside the fluoroscopic field of view [J].
Granger, WE ;
Bednarek, DR ;
Rudin, S .
MEDICAL PHYSICS, 1997, 24 (05) :703-707
[5]
Measured scattered x-ray energy spectra for simulated irradiation geometries in diagnostic radiology [J].
Marshall, NW ;
Faulkner, K ;
Warren, H .
MEDICAL PHYSICS, 1996, 23 (07) :1271-1276
[6]
MARX DL, 1995, 1995 AAPM ANN M
[7]
Prevalence of spinal disc disease among interventional cardiologists [J].
Ross, AM ;
Segal, J ;
Borenstein, D ;
Jenkins, E ;
Cho, SA .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (01) :68-&
[8]
Secondary shielding barriers for diagnostic X-ray facilities: Scatter and leakage revisited [J].
Simpkin, DJ ;
Dixon, RL .
HEALTH PHYSICS, 1998, 74 (03) :350-365
[9]
Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories [J].
Vaño, E ;
González, L ;
Beneytez, F ;
Moreno, F .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847) :728-733
[10]
EVALUATION OF TUNGSTEN AND LEAD SURGICAL GLOVES FOR RADIATION PROTECTION [J].
VANO, E ;
FERNANDEZ, JM ;
DELGADO, V ;
GONZALEZ, L .
HEALTH PHYSICS, 1995, 68 (06) :855-858