Solute affinity in ion-exchange displacement chromatography

被引:42
作者
Brooks, CA [1 ]
Cramer, SM [1 ]
机构
[1] RENSSELAER POLYTECH INST,HOWARD P ISERMANN DEPT CHEM ENGN,TROY,NY 12180
基金
美国国家科学基金会;
关键词
D O I
10.1016/0009-2509(95)00287-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this paper a new graphical method, derived from the Steric Mass Action model of non-linear ion-exchange chromatography, is presented for the determination of solute affinity in ion exchange displacement systems. The affinity of solutes in these systems is described by a dynamic affinity parameter which is a function of the linear steric mass action parameters of the solutes and the characteristic velocity of the displacer front. This method can be employed to determine the elution order of the feed solutes in the isotachic displacement train as well as the ability of a given molecule to act as a displacer for a given protein mixture. The ideal model of ion-exchange displacement chromatography and a transient model are employed to study selectivity reversals and resolving power in ion-exchange displacement systems. The work presented here provides a theoretical framework for studying dynamic affinity, resolving power, and displacer design for ion-exchange displacement chromatography. Copyright (C) Elsevier Science Ltd.
引用
收藏
页码:3847 / 3860
页数:14
相关论文
共 31 条
[1]   A VERSATILE MODEL FOR SIMULATION OF REACTION AND NONEQUILIBRIUM DYNAMICS IN MULTICOMPONENT FIXED-BED ADSORPTION PROCESSES [J].
BERNINGER, JA ;
WHITLEY, RD ;
ZHANG, X ;
WANG, NHL .
COMPUTERS & CHEMICAL ENGINEERING, 1991, 15 (11) :749-768
[2]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[3]  
BROOKS CA, 1993, THESIS RENSSELAER PO
[4]   RECENT ADVANCES IN THE THEORY AND PRACTICE OF DISPLACEMENT CHROMATOGRAPHY [J].
CRAMER, SM ;
SUBRAMANIAN, G .
SEPARATION AND PURIFICATION METHODS, 1990, 19 (01) :31-91
[5]  
CRAMER SM, 1989, NEW DIRECTIONS SORPT
[6]  
CRAMER SM, 1993, ASC S SERIES, V529
[7]  
Cramer Steven M., 1993, Current Opinion in Biotechnology, V4, P217, DOI 10.1016/0958-1669(93)90128-J
[8]   COMPARISON OF MAXIMUM PRODUCTION-RATES AND OPTIMUM OPERATING DESIGN PARAMETERS IN OVERLOADED ELUTION AND DISPLACEMENT CHROMATOGRAPHY [J].
FELINGER, A ;
GUIOCHON, G .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (01) :134-147
[9]  
Finlayson B.A., 1980, NONLINEAR ANAL CHEM
[10]   HIGH-PERFORMANCE DISPLACEMENT CHROMATOGRAPHY - CALCULATION AND EXPERIMENTAL-VERIFICATION OF ZONE DEVELOPMENT [J].
FRENZ, J ;
HORVATH, C .
AICHE JOURNAL, 1985, 31 (03) :400-409