Examination of the myoelectric activity of back muscles during random vibration -: methodical approach and first results

被引:14
作者
Blüthner, R [1 ]
Seidel, H [1 ]
Hinz, B [1 ]
机构
[1] Fed Inst Occupat Safety & Hlth, Dept Occupat Hlth, Grp AM 4 3, D-10317 Berlin, Germany
关键词
EMG; back; vibration; ECG; artefact; wavelet; transfer function;
D O I
10.1016/S0268-0033(00)00098-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To elaborate methods for an elimination of artefacts and the analysis of the relationship between random whole-body vibration and electromyographic responses of back muscles. Design. A procedure involving wavelets and digital filtering has been used for the removal of artefacts from the electromyogram during whole-body vibration. Background. Back muscle forces contribute essentially to the whole-body vibration-induced spinal load. The electromyogram can help to estimate these forces during whole-body vibration. Methods. 38 subjects were exposed to identical random low-frequency whole-body vibration. Artefacts caused by the electrocardiogram in the electromyogram were identified by appropriate wavelets and eliminated in the time-domain. After averaging the individual high-pass filtered and rectified undistorted electromyograms across subjects, the transfer function from seat acceleration to the average electromyogram was determined and used for the prediction of the electromyogram. Results. A sufficient procedure involving wavelets and digital filtering has been elaborated for the removal of artefacts from the electromyogram of back muscles during whole-body vibration. A systematic relationship between random vibration and back muscle-response was obtained and described. The transfer function suggests two different reflex-mechanisms - one elicited below, the other above 4 Hz. Conclusions. The approach of analysing and predicting the muscle-response to random vibration by using the transfer function seems to be promising and could be a valuable tool for the future calculation of muscle forces as an input to active models.
引用
收藏
页码:S25 / S30
页数:6
相关论文
共 16 条
[1]  
Blüthner R, 1998, J LOW FREQ NOISE V A, V17, P215
[2]  
Bluthner R, 1993, International Journal of Industrial Ergonomics, V12, P49, DOI [10.1016/0169-8141(93)90037-E, DOI 10.1016/0169-8141(93)90037-E]
[3]  
BLUTHNER R, 1998, SICHER SICHER, V5, P223
[4]  
BLUTHNER R, 1988, MED SPORT, V28, P154
[5]  
BLUTHNER R, 1997, UK GROUP M RESP VIBR, P61
[6]  
CHAFFIN DB, 1991, OCCUPATIONAL BIOMECH, P518
[7]  
*ISO, 1985, 26311 ISO, P17
[8]   THE MORPHOLOGY OF THE LUMBAR ERECTOR SPINAE [J].
MACINTOSH, JE ;
BOGDUK, N .
SPINE, 1987, 12 (07) :658-668
[9]   THE MORPHOLOGY OF THE HUMAN LUMBAR MULTIFIDUS [J].
MACINTOSH, JE ;
VALENCIA, F ;
BOGDUK, N ;
MUNRO, RR .
CLINICAL BIOMECHANICS, 1986, 1 (04) :196-204
[10]  
MACINTOSH JE, 1991, SPINE, V16, P658